Time necessary to deplete fuel from carburettor system is about 30 sec.

3.3.10. Electrical fire - in flight

1.
Toggle switches, Avionics - switch "OFF"
2.
Magneto A and B switches – switch "OFF"
3.
Master switch - switch "OFF"
4.
Ventilation - OPEN
5.
Perform an Emergency landing to terrain (according to Art. 3.3.2) as soon as possible without using flaps
(Master switch is "OFF")
- Land with increased airspeed!

3.3.11. Loss of oil pressure

On ground
1.
Immediately stop the engine and check reason. Check oil system.
2.
Check oil quality
3.
A maintenance inspection should be carried out
In flight
1.
Throttle - reduce to minimum necessary for flight
2.
Carry out an Emergency landing to terrain (according to 3.3.2)
Be prepared for engine failure and Emergency landing to terrain (see Art. 3.3.2)
3.3.12. High oil pressure
On ground
The oil pressure may achieve maximum value for a short time after engine start during extreme cold conditions.
Apply the following procedure:
Do not attempt to restart the engine after extinguishing fire!