APPENDIX C: MPS-482HP SPECIFICATIONS

MPS-482HP SPECIFICATIONS

FRONT PANEL
LEDs
Fuse
REAR PANEL
Audio Inputs
Channel Outputs
Output Wiring
Output Voltage
AC POWER
AC Connector
Voltage Selection
Safety Rated Voltage Range
CURRENT DRAW
Idle Current
PHYSICAL
Dimensions
Weight
Rigging
ENVIRONMENTAL
Operating Temperature
Non-operating Temperature
Humidity
Operating Altitude
Non Operating Altitude
Shock
Vibration
Two LEDs to indicate presence of output voltage
Two LEDs to indicate load current
Two LEDs to indicate blown or open fuse
Use only Meyer Sound PN 420.041 when replacing
Two XLR 3-pin female connectors or one 6-position Phoenix connector (not summing to the
XLR inputs)
One Link Switch. Sends signal from channel 1 input to channel 2
Two Phoenix 5-pin male connectors
Two pins for DC power, three pins for balanced audio
Pin 1: 48 V DC -
Pin 2: 48 V DC +
Pin 3: Chassis/earth through 220 kOhm, 1000 pF, 15 V clamp network to provide virtual
ground lift at audio frequencies
Pin 4: Audio signal -
Pin 5: Audio signal +
48 V DC per channel (supports NEC class 2 wiring)
powerCON 20
Automatic
100–240 V AC; 50–60 Hz
0.139 A (115 V AC, 60 Hz); 0.071 A (230 V AC, 50 Hz); 0.150 A rms (100 V AC, 60 Hz)
1RU in height x 1/2 width rack mount
W: 8.50 in (216 mm) x H: 1.85 in (47 mm) x D: 8.62 in (219 mm)
4.4 lbs (2 kg)
M6 threads on sides and bottom to support mounting; Optional MUB-MPS-482 U bracket for
flat
surface mounting; Optional RMT-MPS-482 Rack Mount Tray for mounting two MPS-482HPs
in a
standard 19-inch, 2 RU rack slot
0° C to +45° C
–40° C to +75° C
To 95% at 35° C
To 5,000 m (16404 ft)
To 6,300 m (25,000 ft)
30 g 11 msec half-sine on each of 6 sides
10–55 Hz (0.010 m peak-to-peak excursion)