Grundfos Oxiperm 164 D Quick Reference Manual

Grundfos Oxiperm 164 D Quick Reference Manual

Batch mode

Advertisement

Quick Links

SYSTEM DESIGN

3
1
9
2
8
5
ClO
NaClO
2
Oxiperm® 164 D Batch operation
1 Oxiperm® 164 D electronics
2 Connection for bypass water input
3 Connection for the ClO2 solution line
output to the injection unit
4 Suction line for the HCl dosing pump
5 Suction line for NaClO2 dosing pump
6 Shutt-off valve (by customer)
7 Shut-off valve (by customer)

PERFORMANCE AND CONSUMPTION DATA

ClO
p
2
max
preparation
capacity
[bar]
[g/h]
50 Hz
60 Hz
30
10
10
120
9
6
220
7
7
350
9
9
700
9
9
1000
9
9
1500
9
9
2000
9
6
* This quick guide does not replace the IOM. Please refer to the IOM product detailed technical instructions
6
14
13
12
7
4
HCl
2
8 Exhaust system for supporting rack (optional)
9 Dilution tank with level monitoring (optional)
for batch operation
10 Solenoid valve
11 Flow meter
12 Precursor check valves
13 Reaction chamber
14 Ball check valve
15 Back pressure valve
Consumption of
Consumption of bypass water [l/h]
components
(input pressure < p
[l/h]
continuous
operation
HCl
NaClO
2
0.7
420
2.9
420
5.2
420
8.3
420
16.5
900
24
900
35
900
48
900
grundfos Oxiperm batch mOde
3
15
P
P
A
A
2
11
10
Weight
)
max
batch operation *)
[kg]
0.5 - 2 g/l
2 - 3.3 g/l
14
14 - 7.7
33
55
55 - 31
34
100
100 - 56
34
160
160 - 89
57
320
320 - 179
62
450
450 - 258
66
680
680 - 383
76
900
900 - 517
82
quick reference guide
Type
164-030D (DFI)
164-120D (DFI)
164-220D (DFI)
164-350D
164-700D
164-1000D
164-1500D
164-2000D

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Oxiperm 164 D and is the answer not in the manual?

Questions and answers

Summary of Contents for Grundfos Oxiperm 164 D

  • Page 1 Oxiperm batch mOde quick reference guide SYSTEM DESIGN NaClO Oxiperm® 164 D Batch operation 8 Exhaust system for supporting rack (optional) 1 Oxiperm® 164 D electronics 9 Dilution tank with level monitoring (optional) for batch operation 2 Connection for bypass water input...
  • Page 2 GRuNDFOS Oxiperm batch mOde QUICK REFERENCE GUIDE SERVICE OPERATION STARTUP MODE STARTING UP batch concentration automatic mode Main Menu Service Mode Startup Mode Batch Enter Concentration Concentration Main Menu Automatic F1=> Mode bypass Water manual mode Bypass Water Enter Limit...
  • Page 3 GRuNDFOS Oxiperm batch mOde QUICK REFERENCE GUIDE CONTROL AND DISPLAY ELEMENTS SERVICE HOLD MIN. MANU HOLD EXT. AUTO ALARM NaClO 2 LEGEND DISPLAY MENU item1 •••••••••••• LED - dosing controller for NaClO2 flow Auto Mode Manual Mode Logbook LED flashes with correctly set dosing controller Main Menu item2 ••••••••••••...
  • Page 4 Fax: (913) 227-3500 Phone: (905) 829-9533 Phone: 011-52-81-8144 4000 Fax: (905) 829-9512 Fax: 011-52-81-8144 4010 www.grundfos.us The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide.

Table of Contents