1. Check items
1) Is the sensor connected correctly?
2) Is the sensor placed correctly?
4) Is the resistance value of sensor connection pull-up correct?
2. Check procedure
Is the sensor
connector connected correctly in accordance
with a color?
Is the sensor
temperature of 25°C?
Connect the sensor to PBA connector
sensor in the connector.
Micom error or connector check.
Exchange the Outdoor PBA.
Samsung Electronics
Yes
Yes
No
Yes
No
Reconnect the sensor connector.
Sensor Replace
No
Yes
Exchange the Outdoor PBA.
Troubleshooting
30°C - 8.31kohm
35°C - 6.94kohm
40°C - 5.83kohm
4-37