Outdoor Unit - Samsung AR07TSFABWKN Service Manual

Multi air conditioner
Hide thumbs Also See for AR07TSFABWKN:
Table of Contents

Advertisement

Troubleshooting

4-1-2 Outdoor Unit

The table below list the self-diagnostic routines. For some of error, you must contact an authorized service center.
If an error occurs during the operation, it is displayed on the outdoor unit PCB MAIN-OUT.
AJ020TXJ2CH, AJ024TXJ3CH
- PCB MAIN - OUT
Error Code
ERROR DUE TO REPEATED ADDRESS SETTING(WHEN 2 OR MORE DEVICES HAS THE SAME
E108
ADDRESS WITHIN THE NETWORK)
E190
PIPE CHECK ERROR
E199
PIPE CHECK OPERATION HAS NOT BEEN COMPLETED
COMMUNICATION ERROR BETWEEN INDOOR AND OUTDOOR UNIT(INSTALLATION NUMBER
E201
SETTING ERROR, REPEATED INDOOR UNIT ADDRESS, INDOOR UNIT COMM
COMMUNICATION ERROR BETWEEN INDOOR AND OUTDOOR UNIT(COMMUNICATION ERROR
E202
ON ALL INDOOR UNITS, OUTDOOR UNIT COMMUNICATION CABLE ERROR)
E203
COMMUNICATION ERROR BETWEEN INVERTER PBA AND MAIN PBA
E221
ERROR ON AMBIENT TEMPERATURE SENSOR (SHORT OR OPEN)
E237
ERROR ON CONDENSOR TEMPERATURE SENSOR(SHORT OR OPEN)
E251
ERROR ON DISCHARGE TEMPERATURE SENSOR(SHORT OR OPEN)
E320
ERROR ON COMPRESSOR OLP TEMPERATURE SENSOR(SHORT OR OPEN)
E330
ERROR ON PIPE IN-A TEMPERATURE SENSOR(SHORT OR OPEN)
E331
ERROR ON PIPE IN-B TEMPERATURE SENSOR(SHORT OR OPEN)
E332
ERROR ON PIPE IN-C TEMPERATURE SENSOR(SHORT OR OPEN)
E333
ERROR ON PIPE IN-D TEMPERATURE SENSOR(SHORT OR OPEN)
E334
ERROR ON PIPE IN-E TEMPERATURE SENSOR(SHORT OR OPEN)
4-4
- PCB MAIN – OUT
(AJ020TXS3CH, AJ***TX*4CH, AJ***TX*5CH)
Explanation
Remark