4. TROUBLE SHOOTING
4.11 Charger Troubleshooting
TA
(5.1V)
Charging Procedure
- Connect TA or USB Cable
- Control the charging current by PM6650 IC
- Charging current flows into the battery
Check Point
- Connection of TA or USB Cable
- Charging current path
- Battery
LGE Internal Use Only
Charging Current Flow
Troubleshooting Setup
- Connect TA and battery to the phone
Troubleshooting Procedure
- Check the charger (TA or USB Cable) connector
- Check the charging current Path
- Check the battery
Copyright © 2008 LG Electronics. Inc. All right reserved.
- 112 -
Pass Tr
Battery FET
Main
4.2~4.25V
Battery
Only for training and service purposes
(ON)
(ON)