CAUTION: DISCONNECT the unit from an electrical power source before performing any
maintenance or cleaning on the unit.
SYSTEM CASE CLEANING
Exterior
The exterior of the Odorox® product can be cleaned with mild dishwashing detergent and a clean cloth,
and then rinsed with clean water. DO NOT use any all‐purpose cleaners with harsh detergents or
abrasives, as these may damage the decals and the exterior finish. Care should also be taken to avoid
spraying or otherwise directing detergent or water into or around electrical components.
Interior
The interior of the Odorox® product can be cleaned in the same manner as the exterior.
OPTIC CLEANING
Cleaning of the optics is recommended to maintain peak processing efficiency. Fingerprints, smudges,
dirt, dust particles, etc. will interfere with the hydroxyl production and should be avoided.
Note: Remove the optics from the optic chamber prior to cleaning to avoid any damage to
the optics during the cleaning process (refer to the Optic Replacement Instructions and Safety
Information for proper removal).
To clean the optics, use a solution of 10% Isopropyl Alcohol and 90% filtered/distilled water on a clean
lint‐free cloth and wipe gently. Do not use any type of commercial glass cleaner. Using another lint‐free
cloth, gently wipe the optic until completely dry. Allow the optic to dry completely before operating the
system.
FILTER CLEANING/REPLACEMENT
The MDU/Rx™ unit comes equipped with a
washable filter. The filter can be easily
removed by first removing the two phillips
(star) screws retaining the filter cover, remove
filter cover and then pull out the filter. The
filter can then be washed clean.
*Note: Allow the filter to totally dry before
operating the MDU/Rx™ unit.
The time between necessary cleaning will
depend on the operating conditions and the
cleanliness of the treatment area. In most
cases, a quick vacuum of the filter is all that is
needed.
CARE INSTRUCTIONS