OPTIC REPLACEMENT INSTRUCTIONS 
Warning:  DISCONNECT the unit from the electrical power source before performing any 
maintenance or cleaning on the MDU/RX™ Unit. 
Caution:  Optics contain Mercury.  Read and follow the Safety Information on pages 2 and 3 
of this manual when handling the optics in the MDU/RX™ unit. 
Step 1 – Turn MAIN POWER switch to the OFF position 
Step 2 – Unplug power cord from the electrical receptacle 
Step 3 – Using the supplied key, unlock and remove both end panels 
Step 4 – Remove filter cover plate and filter 
Step 5 – Remove optics following these instructions: 
Caution:  Use clean powder free latex gloves and eye protection when handling the optics in 
this unit 
 With a firm grip on the upper porcelain end of the optic, use your other hand to grip the
optic connector.
 Gently 'wiggle' connector while pulling from the optic base.
 Gently pull optic from three lamp supports (Do not put any pressure on the side of the
optic without support).
Step 5 – Install new optic following these instructions: 
 Remove new optic from packaging and gently insert into the three optic clips.
 With a firm grip on the upper porcelain end of the optic, use your other hand to grip the
optic connector.
 Gently connect the optic connector to the optic.
Note:  Optic connector is keyed with the optic base and will connect in one direction
only
 Ensure optic connector and optic base are firmly pressed together.
Step 6 – Re‐install end panels and lock with the supplied key 
Step 7 – Re‐install filter and filter plate 
Step 7 – Plug power cord back into the electrical receptacle 
Step 8 – Test unit for proper operation 