Odorox MDU/RX Owner's Manual

Odorox MDU/RX Owner's Manual

Mobile disinfection unit

Advertisement

Quick Links

MDU/RX
MDU/RX
THE ODOROX
MDU/Rx
®
DISINFECTION UNIT) IS SPECIFICALLY
ENGINEERED FOR PROVIDING A
CONCENTRATION OF ODOROX
HYDROXYLS TO TREAT ODORS
ASSOCIATED WITH BACTERIAL, VIRAL AND
MOLD CONTAMINATIONS. MDU/Rx
SUCH AS:
MEDICAL CENTERS
CLINICAL LABORATORIES
INSTITUTIONAL FACILITIES
VETERINARY CARE FACILITIES
HOSPITALS AND SURGICAL CENTERS
The ODOROX
MDU/Rx
Unit is designed for use in
®
occupied spaces ranging from 500-100 square feet
(1,300 to 5,000 cubic feet). It is equipped with 2
ODOROX
hydroxyl generating optics, hour meter and
®
a washable filter.
Mobile Disinfection Unit
UNIT (MOBILE
®
AREAS
190 Summerhill Road | Spotswood NJ 08884 | (732) 251-9506 ext. 211
odoroxair@bio-shine.com | www.OdoroxAir.com
SPECIFICATIONS:
Dimensions: 18.25" x 12.1" x 25.3"
(308mm x 464mm x 641mm)
Weight: 39lbs, 17.7kg
Voltage: 120V @ 50/60 Hz / 220V @ 50/60 Hz
Power: 230 Watts (max)
Mobility: Handle / Rubber feet / Optional wheeled cart
Finish: White powder coat
Noise Level: <40 dBA
Number of Optics: 2
Air Inlet / Outlet: Louvered Panel
Fans & Rating: One 150 CFM
Fan Speed : 140 ft³/m
(based on 230VAC, 50Hz fan set on high speed)
Filter: One 9" x 18" x 1"
(228.6mm x 457.22mm x 25.4mm), Washable
Certification: FDA Approved, Meets Canada / US – CSA &
UL Standards, Meets CE, REACH, & RoHS, Residual O
Non-accumulative
FDA APPROVED
GREEN TECHNOLOGY AT WORK
OWNER'S MANUAL
25
/
3

Advertisement

loading

Summary of Contents for Odorox MDU/RX

  • Page 1 Voltage: 120V @ 50/60 Hz / 220V @ 50/60 Hz HYDROXYLS TO TREAT ODORS • Power: 230 Watts (max) ASSOCIATED WITH BACTERIAL, VIRAL AND • Mobility: Handle / Rubber feet / Optional wheeled cart MOLD CONTAMINATIONS. MDU/Rx AREAS ™ • Finish: White powder coat SUCH AS: •...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS  SAFETY INFORMATION    1  CONTENTS LIST      4  ODOROX® MDU/RX™ UNIT OPERATIONAL GUIDELINES      5 OPERATING THE ODOROX® MDU/RX™ UNIT      6  CARE INSTRUCTIONS      7  OPTIC REPLACEMENT INSTRUCTIONS      8  TROUBLESHOOTING GUIDE      9  SPECIFICATIONS, REPLACEMENT PARTS AND WARRANTY   10 ...
  • Page 3: Safety Information

    • Use generator only for intended use as described in MDU/Rx™ device not be used in areas that this manual. Any other use not recommended by the generate x-ray radiation or be placed behind manufacturer may cause fire, electric shock, or injury shields used by technicians in these areas.
  • Page 4 SAFE HANDLING AND DISPOSAL OF MERCURY Mercury is used in the MDU/Rx™ device in order to generate the plasma needed to produce UV-C radiation. This is similar to the use of mercury in many types of commercial, fluorescent light fixtures. As long as the glass or quartz outer bulb is intact, mercury is contained within the fixture and poses no health hazard.
  • Page 5 SAFETY INFORMATION  Use the eyedropper to collect mercury beads and place them in the plastic bag. Hold the eyedropper at an angle to draw the at the beginning of the cleanup. Close the mercury into the tip. Keep the eyedropper at trash bag and take it outdoors.
  • Page 6: Contents List

    CONTENTS LIST  1) One Odorox MDU™/Rx Hydroxyl Generator c/w Pre‐Filter 2) One Owner’s Manual 3) One Warranty Card 4 ...
  • Page 7: Odorox® Mdu/Rx™ Unit Operational Guidelines

    ODOROX® MDU/RX™ UNIT OPERATIONAL GUIDELINES  The Odorox® MDU/RX™ Unit is  the right choice for hospitals,  outpatient surgery centers,      doctor’s offices, urgent care  centers, nursing homes and  other medical facilities.  The Odorox® MDU/RX™ Unit is designed for light to medium concentration processing and  operates using less than 120 Watts (refer to Specification page for additional ratings).  The  MDU/RX™ Unit is equipped with a selector switch which turns on 2 Odorox® hydroxyl  generating optics and the built‐in fan.  This fan is rated to deliver 150 cubic feet per minute  (254.8 cubic meters per hour).  With a manufacturer’s specification of less than 0.3 Sones*, this  fan is ideal where very quiet operation is desired.  Examples of possible treatment applications  could be hospital rooms, operating rooms, nurse stations, break rooms, small waiting rooms  and offices.  For optimal results the recommended treatment space is from 170 square feet (15.7 square  meters) up to 500 square feet (46.4 square meters) with air exchange rates typically found in  medical facilities.  *HVI Certified performance based on HVI Procedures 915, 916, and 920. 5 ...
  • Page 8: Operating The Odorox® Mdu/Rx™ Unit

    OPERATING THE ODOROX® MDU/RX™ UNIT  POWER ON  The main power for the MDU/Rx™ Unit can be switched on by turning the MAIN POWER switch to the  ON position.  POWER OFF  The main power for the MDU/Rx™ Unit can be switched off by turning the MAIN POWER switch to the  OFF position.  FAN SPEED  The MDU/Rx™ Unit is equipped with an air mover fan, which is designed to deliver 150 cubic feet per  minute (254.8 cubic meters per hour).  In order for the fan to turn on, the MAIN POWER switch must be in the ON position.  PROCESSOR   The MDU/Rx™ Unit is equipped with two hydroxyl generating optics.  In order for the optics to turn on,  the MAIN POWER switch must be in the ON position.    Two blue LED indicators are located next to the MAIN POWER switch to provide optic status to the  operator.  While the optics are functioning normally, the blue LED indicators will be illuminated (see  TROUBLESHOOTING GUIDE for recommendations when indicators are not illuminated with the unit in  the ON position).  HOUR METER  The MDU/Rx™ Unit is equipped with a digital meter that monitors the hour usage of the unit.  This is  beneficial for monitoring the life of the optics, length of treatment time, maintenance and cleaning  cycles.  6 ...
  • Page 9: Care Instructions

    CARE INSTRUCTIONS  CAUTION:  DISCONNECT the unit from an electrical power source before performing any  maintenance or cleaning on the unit.  SYSTEM CASE CLEANING  Exterior  The exterior of the Odorox® product can be cleaned with mild dishwashing detergent and a clean cloth,  and then rinsed with clean water.  DO NOT use any all‐purpose cleaners with harsh detergents or  abrasives, as these may damage the decals and the exterior finish.  Care should also be taken to avoid  spraying or otherwise directing detergent or water into or around electrical components.  Interior  The interior of the Odorox® product can be cleaned in the same manner as the exterior.  OPTIC CLEANING  Cleaning of the optics is recommended to maintain peak processing efficiency.  Fingerprints, smudges,  dirt, dust particles, etc. will interfere with the hydroxyl production and should be avoided.  Note:  Remove the optics from the optic chamber prior to cleaning to avoid any damage to  the optics during the cleaning process (refer to the Optic Replacement Instructions and Safety  Information for proper removal).  To clean the optics, use a solution of 10% Isopropyl Alcohol and 90% filtered/distilled water on a clean  lint‐free cloth and wipe gently.  Do not use any type of commercial glass cleaner.  Using another lint‐free  cloth, gently wipe the optic until completely dry.  Allow the optic to dry completely before operating the  system.  FILTER CLEANING/REPLACEMENT  The MDU/Rx™ unit comes equipped with a  washable filter.  The filter can be easily  FILTER COVER  removed by first removing the two phillips  (star) screws retaining the filter cover, remove  filter cover and then pull out the filter.  The  filter can then be washed clean.    *Note:  Allow the filter to totally dry before operating the MDU/Rx™ unit. The time between necessary cleaning will  depend on the operating conditions and the  cleanliness of the treatment area.  In most  cases, a quick vacuum of the filter is all that is    needed. 7 ...
  • Page 10: Optic Replacement Instructions

    OPTIC REPLACEMENT INSTRUCTIONS  Warning:  DISCONNECT the unit from the electrical power source before performing any  maintenance or cleaning on the MDU/RX™ Unit.  Caution:  Optics contain Mercury.  Read and follow the Safety Information on pages 2 and 3  of this manual when handling the optics in the MDU/RX™ unit.  Step 1 – Turn MAIN POWER switch to the OFF position  Step 2 – Unplug power cord from the electrical receptacle  Step 3 – Using the supplied key, unlock and remove both end panels  Step 4 – Remove filter cover plate and filter  Step 5 – Remove optics following these instructions:  Caution:  Use clean powder free latex gloves and eye protection when handling the optics in  this unit   With a firm grip on the upper porcelain end of the optic, use your other hand to grip the optic connector.  Gently ‘wiggle’ connector while pulling from the optic base.  Gently pull optic from three lamp supports (Do not put any pressure on the side of the optic without support). Step 5 – Install new optic following these instructions:   Remove new optic from packaging and gently insert into the three optic clips.  With a firm grip on the upper porcelain end of the optic, use your other hand to grip the optic connector.  Gently connect the optic connector to the optic. Note:  Optic connector is keyed with the optic base and will connect in one direction only  Ensure optic connector and optic base are firmly pressed together. Step 6 – Re‐install end panels and lock with the supplied key  Step 7 – Re‐install filter and filter plate  Step 7 – Plug power cord back into the electrical receptacle  Step 8 – Test unit for proper operation  8 ...
  • Page 11: Troubleshooting Guide

    TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION Fan will not turn on MDU™/RX Unit is not plugged Ensure circuit breaker is 'ON' and the into an energized electrical electrical receptacle has proper power receptacle. available. Internal component failure. Contact local distributor for service. Blue OPTIC 1 or MAIN POWER switch is in the Turn on MAIN POWER switch to the ON...
  • Page 12: Specifications, Replacement Parts And Warranty

    SPECIFICATIONS  Dimensions:  12.5” x 18.5” x 25” (307mm x 470mm x 635mm)  Weight:  28lbs (12kg)  Power Requirements:   120 Volt AC, 120 Watt, 60 Hz   (Model # MDURXTAAK)   210 – 240 Volt AC, 120 Watt, 50/60 Hz  (Model # MDIRXTAAK)  Control:  MAIN POWER Selector Switch  Fan Rating:  150 Cubic Feet per Minute (254.8 Cubic Meters per Hour)  :     Noise Level <0.3 Sones Meter:  Digital Hour Meter    Mobility:  Handle/Rubber Feet, Optional Wheeled Cart Number of Optics:  2  REPLACEMENT PARTS  LIMITED WARRANTY  HGI Industries, Incorporated warrants that this Odorox® product (excluding spare parts and  consumables) shall be free from defects in workmanship or materials for a period of one (1)  year from the delivery thereof to the customer.  10 ...