CONJUNTO UCM/
UCM UNIT/
ENSEMBLE UCM/
BAUGRUPPE UCM/
D-BOX + QUASAR T25 A3 +
ASG UD
INSTRUCCIONES DE USO Y MANUTENCIÓN/
INSTRUCTIONS FOR USE AND MAINTENANCE/
INSTRUCTIONS D'USAGE ET ENTRETIEN/
GEBRAUCHS- UND WARTUNGSANLEITUNG/

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D-BOX and is the answer not in the manual?

Questions and answers

Summary of Contents for Dynatech D-BOX

  • Page 1 CONJUNTO UCM/ UCM UNIT/ ENSEMBLE UCM/ BAUGRUPPE UCM/ D-BOX + QUASAR T25 A3 + ASG UD INSTRUCCIONES DE USO Y MANUTENCIÓN/ INSTRUCTIONS FOR USE AND MAINTENANCE/ INSTRUCTIONS D’USAGE ET ENTRETIEN/ GEBRAUCHS- UND WARTUNGSANLEITUNG/...
  • Page 3 OPERATION AS A UNIT ..........................3  ASSEMBLY AND MAINTENANCE ......................6 _________________________________________________________ Note: This manual displays partial information on the instructions for use and maintenance of this product. Please refer to the customer area in Dynatech’s website in order to consult the full manual; http://customers.dynatech-elevation.com/...
  • Page 4  The D-Box + QUASAR T25 A3 + ASG UD unit is valid for installations where the P/Q ratio is above 0.7.  When a UCM occurs, a qualified technician is required for the installation to be operative again. Once the problem causing the UCM has been solved, the reset button must be pressed in order to restore the safety series and for the system to be operative again.
  • Page 5 D-Box’s input signals are typical of the installation controller. As a result, response times of the controller components are inherent to it even though the total response times of the D-Box + QUASAR T25 A3 + ASG UD unit are considered as standard.
  • Page 6 UCM, and a micro-switch, which indicates the interlocking system’s positioning to the D-Box. Note: This manual displays partial information on the instructions for use and maintenance of this product. Please refer to the customer area in Dynatech’s website in order to consult the full manual; http://customers.dynatech-elevation.com/...
  • Page 7 By using these inputs, if the D-Box detects that the car leaves door level with doors open, the contactor in the safety line is activated, which causes the QUASAR T25 A3 governor’s parking system coil to de-energise. This will make the parking system interlocking system operate on the governor’s centrifugal systems, thus causing the governor to...
  • Page 8 D-Box: Only specialised and duly trained staff must carry out the assembly, electrical wiring and start-up. For further information on assembly, the characteristics of the electrical wiring and wiring diagrams, please refer to the D-Box’s manual for use and maintenance.