Dynatech D-BOX Instructions For Use And Maintenance Manual

Ucm unit

Advertisement

CONJUNTO UCM/
UCM UNIT/
ENSEMBLE UCM/
BAUGRUPPE UCM/
D-BOX + STAR A3 BETA+ ASG 1XX/ASG
1XX-UD + T-25/T-25UD
INSTRUCCIONES DE USO Y MANUTENCIÓN/
INSTRUCTIONS FOR USE AND MAINTENANCE/
INSTRUCTIONS D'USAGE ET ENTRETIEN/
GEBRAUCHS- UND WARTUNGSANLEITUNG/

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D-BOX and is the answer not in the manual?

Questions and answers

Summary of Contents for Dynatech D-BOX

  • Page 1 CONJUNTO UCM/ UCM UNIT/ ENSEMBLE UCM/ BAUGRUPPE UCM/ D-BOX + STAR A3 BETA+ ASG 1XX/ASG 1XX-UD + T-25/T-25UD INSTRUCCIONES DE USO Y MANUTENCIÓN/ INSTRUCTIONS FOR USE AND MAINTENANCE/ INSTRUCTIONS D’USAGE ET ENTRETIEN/ GEBRAUCHS- UND WARTUNGSANLEITUNG/...
  • Page 3 D-Box + Star A3 Beta+ ASG 1XX + T-25 Instruction Manual Code: DYN 62-2.05 Date: 20/12/2019 Revision: 05 INSTRUCTIONS FOR USE AND MAINTENANCE _________________________________________________________ INTRODUCTION ..............................2 1.1. DESCRIPTION ............................. 2 RISKS AND SECURITY WARNINGS ......................... 2 2.1. RISKS ................................2 2.2.
  • Page 4: Security Warnings

    Reference to the manuals for use and maintenance of the different components making up the unit is recommended before their installation. • The D-Box + Star A3 Beta + ASG 1XX/ASG 1XX-UD + T-25/T-25 UD unit is valid for installations where the P/Q ratio is above 0.7. •...
  • Page 5: Description Of The Unit

    OPERATION AS A UNIT As can be seen in figure 2, the D-Box electronic device is connected to the installation controller and the Star A3 governor’s parking system. D-Box connection is described in the D-Box's manual for use and maintenance.
  • Page 6 As displayed in figure 3, the Star A3 Beta governor is connected to the T-25/T-25 UD steering mechanism via an auxiliary part. This part, not supplied by Dynatech, must be designed so that the drive does not have clearance or cause extra travel.
  • Page 7 Figure 4: Star A3 Beta Governor The protection of this system against UCM is as follows: The D-Box electronic system compares, at all times, the status of the car doors and the floor level via input signals from the installation. These signals are: •...
  • Page 8: Assembly And Maintenance

    By using these inputs, if the D-Box detects that the car leaves door level with doors open, the contactor in the safety line is activated, which causes the Star A3 Beta governor’s parking system coil to de-energise. This will make the parking system interlocking system operate on the governor’s centrifugal systems, thus causing the governor to...
  • Page 9 D-Box + Star A3 Beta+ ASG 1XX + T-25 Instruction Manual Code: DYN 62-2.05 Date: 20/12/2019 Revision: 05 Please check the distance from the safety gear brake shoe to the guide rail. Please also check that the auxiliary part connecting the Star A3 Beta governor to the T-25/ T-25 UD steering mechanism is suitably fitted and operates correctly.