Applied Comfort SD Installation & Operation Manual

Applied Comfort SD Installation & Operation Manual

Downflow ducted packaged terminal, heating and cooling unit, cooling - only unit

Advertisement

Quick Links

SD DOWNFLOW DUCTED PACKAGED TERMINAL AIR CONDITIONERS
Heating and Cooling Unit
Cooling - Only Unit
INSTALLATION & OPERATION MANUAL
Effective February 1985 (Revision Date: April 2009)
This manual supersedes all previous issues.
801108 REV. 01 APR 2009

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Applied Comfort SD

  • Page 1 SD DOWNFLOW DUCTED PACKAGED TERMINAL AIR CONDITIONERS Heating and Cooling Unit Cooling - Only Unit INSTALLATION & OPERATION MANUAL Effective February 1985 (Revision Date: April 2009) This manual supersedes all previous issues. 801108 REV. 01 APR 2009...
  • Page 2: Table Of Contents

    Before Each Heating and Cooling Season: ................... 9 WARNING: SAFETY HAZARD THE SD SERIES UNITS MUST BE USED FOR DUCTED APPLICATIONS ONLY. FREE AIR DISCHARGE APPLICATIONS REQUIRE THE SU SERIES, WHICH IS A SPECIALLY CONFIGURED UNIT, SIMILAR IN APPEARANCE, BUT WHICH INCORPORATES A DISCHARGE GRILLE AND OTHER SAFETY FEATURES REQUIRED FOR FREE AIR DISCHARGE APPLICATIONS.
  • Page 3: Components

    COMPONENTS applicable) extends from the left 1. Wall Sleeve & Outdoor 5. Ducting side of the control section located Grille The vertical side ducts come on the right hand side of the unit. The wall sleeve is to be built into complete with a duct collar on the This cord is to be attached to a the wall during construction.
  • Page 6 This cord is to be attached to a duct. The unit must be ducted out Wall Sleeve & Outdoor Grille field – supplied receptacle both sides. The interior of the The wall sleeve is to be built into mounted in the factory – supplied flanking duct must be insulated the wall during construction.
  • Page 7: Installation

    INSTALLATION INSTALLATION OF THE least 8” of free wire inside the IMPORTANT: The wall sleeve CABINET AND WALL SLEEVE conduit box to facilitate must possess an overall ¼” 1. The cabinet/wall sleeve may be connections. slope downward toward the positioned in the wall to suit the outside to ensure proper water 6.
  • Page 8: Power & Control Wiring

    INSTALLATION 10. Install the unit air filter into POWER & CONTROL WIRING 3. Unpack heat/cool chassis from 1. Connect power supply for the shipping carton. Check for any position. unit to the correct terminals of shipping damage. NOTE: Ensure that the cord is the receptacle.
  • Page 9: Operating Instructions

    OPERATING INSTRUCTIONS The Unitary Package Heating, terminal, typically if its display is fan switch is set to “ON”, the indoor Cooling Unit has been carefully backlit. If the thermostat demands fan will circulate air continuously on designed and built to provide that the “C”...
  • Page 10: Operating Procedures

    OPERATING PROCEDURES PLACE ARTICLES ON 1. Ensure that controls are SUGGESTED OPERATING properly set. DISCHARGE REGISTERS. PROCEDURES 2. Check to see if a fuse has 6. When adjusting the thermostat, To obtain the maximum comfort be careful not to over control. blown or a breaker has tripped.