IDEC SE1L Manual page 3

Safety laser scanner
Table of Contents

Advertisement

Muting
Muting function enables flexible setting of protection zones
Function
Specific areas of the protection zone
can be disabled by the muting sensor.
Complicated protection zones can be
configured easily.
Override
Override function enables safe restart of factory lines
Function
With the override function, when a
light curtain is interrupted by an object
or when a line stops before muting
conditions are established (when only
one muting sensor is interrupted),
the object interrupting the light does
not have to be removed. Therefore,
the line can be started smoothly and
safely.
Reference monitor function detects misalignment
By configuring a reference point,
moving parts such as doors can
be detected when SE1L is not
correctly positioned, and turns off
the safety output (OSSD). Because
the misalignment of the SE1L can be
detected, hazardous areas can be
avoided, enhancing safety.
(14/04/28)
Some areas were
disabled even when
protection was needed
When light curtains are used
No Override Function
Object must be removed for restart
Output OFF when
door opens
Protection area
SE1L
Output OFF when mounting SE1L is misaligned
Reference
area
Floor
Hazardous areas are
before
minimized, enhancing
safety
When laser scanner is used
(image)
Override Function
Starts smoothly
Remove
Object
When a moving part is set as a reference point, the
output turns OFF when the door is opened.
Reference area
Moving
part
SE1L
Reference
area
Protection
area
SE1L
(image)
No need
to remove
object
Moving
part
SE1L
Misalignment
Floor
3

Advertisement

Table of Contents
loading

Table of Contents