Input/Output Circuit; Safety Precautions - IDEC SE1L Manual

Safety laser scanner
Table of Contents

Advertisement

SE1L
Safety Laser Scanner
Wiring Example
Wiring Example
+24V DC (brown)
0V DC (blue)
OSSD1 (red)
OSSD2 (yellow)
IN_A (purple)
IN_A (purple/black)
IN_B (gray)
IN_B (gray/black)
IN_C (white)
IN_C (white/black)
IN_D/MUTING_1 (pink)
IN_D/MUTING_2 (pink/black)
WARNING1 (red/black)
WARNING2/ERR/MUT_OUT (yellow/black)
READY/RES_REQ (orange)
EDM (green)
RESET (green/black)
OVERRIDE (orange/black)
FG (shielded wire)
R1, R2: External device (safety relay, magnet contactor, etc.)
S1: Interlock reset switch
*1: See page 9 for area switching.
x For details on the wire colors and function, see page 17.

Safety Precautions

Safety Precautions
For correct use of the SE1L, take note of the following
precautions.
x SE1L is a AOPDDR (Active Optoelectronic Protective
Device responsive to Diffuse Reflection) that detects
diffused emitted light within the protection zone. The
emitted light is irradiated within the protection zone by
the rotating motor and reflects back from the objects as
diffused reflective light and is detected by the receiving
unit of the SE1L.
x Perform tests before operation to check the function and
performance of the SE1L.
x Use the SE1L within the specification range described
in the manual. To prevent degradation of detection
characteristics, make sure that maintenance is carried
out.
x To maintain the degree of protection, do not modify or
disassemble the SE1L.
x The operator must be a person qualified to operate
the SE1L. The operator must be trained and be able to
operate the SE1L correctly.
x The administrator must provide continuous training to the
operator for correct use of the SE1L.
x When using the SE1L in a safety-related system, the
administrator must be responsible for following safety
requirements, standards, rules, regulations, and laws of
each country, state, or district.
x The administrator must understand the manual and be
responsible for ensuring appropriate operating conditions
for SE1L.
18
R1
R2
R2
R1
S1
S2
x To examine the object detecting performance, use a
test piece the size equivalent to the minimum detectable
object.
x Error occurs when detection capability is below 30% due
to homogenous dirt on the optical window. The operator
must keep the windows clean
x While SE1L is removed, a protective measure must
be taken to ensure safety within the protection zone.
To prevent entry into the danger zone, use protective
materials such as a safety guard or light curtain.
x Dispose the SE1L as industrial waste or in accordance
with the local regulations.
x Do not perform withstand voltage tests or insulation
resistance tests. Varistors that are used in power circuits
may be damaged.
Operating Environment
x Make sure that the operating environment is within
the range of the specifications (temperature, humidity,
vibration, light interference).
x Do not use the SE1L near a machine that may generate
strong radio waves. It may interfere with the operation of
the SE1L.
x Do not use or install the SE1L where dust, smoke, or
corrosive chemical substances exist. Using the SE1L
under these environments may lead to degradation of
detection performance.
x When the interlock function is active, make sure that the
surrounding environment, especially within the protection
zone, is safe before resetting the interlock.

Input/Output Circuit

OSSD Output Circuit
OSSD outputs are N channel
MOSFET outputs.
+24V
1
Control
Circuit
Other Output Circuit
WARNING1, WARNING2, READY
outputs are PNP outputs.
+24V
Control
Circuit
Input Circuit
Available for area input, EDM,
RESET, MUTING1, MUTING2, and
OVERRIDE.
Control
Circuit
OSSD1
OSSD2
WARNING1
WARNING2
READY
Input
0V
(14/04/28)