SE1L
Safety Laser Scanner
Muting Override Function
Muting override function is used to temporarily stop all
safety functions of the entire protection zone when the
OSSD turns OFF during muting. The override function
is effective when the override input and reset input is
switched in the order as shown below. When the SE1L
is in a override status, the 7-segment display shows the
override code.
Override start condition
Either one of the muting input is ON.
When an object exists in the protection zone.
When the time interval of the override input and reset
input is between 0.03 and 1 second (T3)
Override stop condition
Both of the muting inputs are OFF.
Either the override input or reset input is OFF.
When the override state exceeds the maximum
override time T4.
When an error is detected by the self-diagnosis
function of the SE1L.
When the muting area switched to a different area
during muting.
Maximum override time (T4)
1 minute
6 minute
12 minute
Override Sequence
ON
Muting1
OFF
ON
Muting2
OFF
ON
Override input
OFF
ON
Reset input
OFF
T3
ON
Override status
OFF
x When the muting function is effective, the user
must ensure the safety of the protection zone.
x Before using the muting function, make sure to
perform a risk assessment.
x If the above procedures are not followed, critical
injury or death may result.
12
T4
60ms
60ms
Reference Monitor Function
The reference monitor function is a function to monitor
the displacement of the SE1L or the structure in the
background used as a reference.
Existence Detection Application Examples
When the reference area is set to a moving part such as
a door, the OSSD will turn OFF if the position of the door
changes.
Reference background
SE1L
Access Detection Application Example
The user must configure the reference area for monitoring.
To detect the displacement, set a reference area on each
side. The OSSD will turn OFF when the distance between
the reference background has changed or when an access
is detected. This function must be used when the SE1L is
installed vertically.
(1) Application Example 1 (front view)
Reference area
Make sure that 2 or
more reference
areas are set to one
side of the reference
background so that
displacement is
detected correctly.
Floor
(2) Application Example 2 (front view)
Reference area
Floor
(Caution) Incorrect reference area configuration (front view)
Reference area
Floor
Protection
zone
Reference area
Moving part
SE1L
Reference background
Protection zone
SE1L
Reference background
Protection zone
SE1L
Reference background
Protection zone
(14/04/28)