Air flue duct

Advertisement

FITTING THE APPLIANCE FLUE OUTLET ADAPTER TO THE BOILER
Connecting the
condensate discharge
system
• A condensate discharge
connection (3) is provided on the
adaptor to remove any
condensate or other water which
may form in the flue system.
• Connect the condensate discharge
tube (2) to the condensate
discharge connection point (4) on
the adaptor and secure with the
plastic rachet clip provided.
Important: Ensure that there are no
kinks in the condensate discharge
pipe.
• Position the trap (5) below the
appliance and secure to the wall
using the bracket and screws
provided. Connect the condensate
discharge tube to the top
connection of the trap ensuring
that the condensate discharge
tube engages into the trap by a
minimum of 90 mm.
• Connect the outlet of the
condensate trap (6) to a suitable
drain point.
Important: Before operating the boiler
the condensate trap must be filled
with water.
• Use only the condensation hose
and condensate trap supplied
with the accessory.