HUMS Accelerometer
Types 4511-W-006 and 4524-W-001
Abbreviated Component Maintenance Manual
Copyright © 2011, Brüel & Kjær Sound & Vibration Measurement A/S
All rights reserved. No part of this publication may be reproduced or distributed in any form or by any means, without prior
written consent from Brüel & Kjær Sound & Vibration Measurement A/S, Nærum, Denmark
BN1100 Revision: 0
Initial Issue: 21/08/2012
ATA 31-10-04
The document reference is online, please check the correspondence between the online documentation and the printed version.

Advertisement

Table of Contents
loading

Summary of Contents for BRUEL & KJAER 4511-W-006

  • Page 1 HUMS Accelerometer Types 4511-W-006 and 4524-W-001 Abbreviated Component Maintenance Manual Copyright © 2011, Brüel & Kjær Sound & Vibration Measurement A/S All rights reserved. No part of this publication may be reproduced or distributed in any form or by any means, without prior written consent from Brüel &...
  • Page 2 List of Revisions: Rev. No. Rev. Date List of Effective Pages: Page 1 of 18 August 2012 Page 7 of 18 August 2012 Page 13 of 18 August 2012 Page 2 of 18 August 2012 Page 8 of 18 August 2012 Page 14 of 18 August 2012 Page 3 of 18...
  • Page 3: Table Of Contents

    Contents SECTION 1 General Description and Operation ....................4 Purpose..............................4 Technical Data ............................6 Specification –Type 4511-W-006........................6 Specification –Type 4524-W-001....................... 8 SECTION 2 Testing............................. 10 General ..............................10 Test Conditions............................10 Procedure ..............................10 Appearance.............................. 11 Transducer Sensivity Control........................11 Electrical Test ............................
  • Page 4: General Description And Operation

    The output provides a voltage signal proportional to the acceleration. It is powered by a constant current line drive supply on the same wire as the output signal. Accelerometer monoaxial 4511-W-006 Fig. 1 Dimensions : All dimensions in millimeters Fig.
  • Page 5 The accelerometer is intended to measure the vibration of the rotor for HUMS purposes on three axes: X, Y and Z. It consists of a triaxial piezoelectric element and an electronic charge converter enclosed in a hermetic housing. The output provides a voltage signal proportional to the acceleration for each axis.
  • Page 6: Technical Data

    Technical Data 1.2.1 Specification – Type 4511-W-006 – Monoaxial General Characteristics Accelerometer Type IEPE – monoaxial Voltage Sensitivity (at 159.2 Hz) 10 mV/g Sensitivity Tolerance ±5% on the whole frequency range Measuring Range ± 500 g pk Output Full Scale Voltage ±5 V...
  • Page 7 Insulation Resistance >100 MΩ Dielectric Strength 500 Vdc Signal Ground Isolated from housing Connection Through a bifilar cable (double-shielded recommended) Single-shielded possible if connected to structure in both ends Environmental Characteristics Temperature Normal Operational Range – 51°C to +150°C Temperature Survival Range –...
  • Page 8: Specification -Type 4524-W-001

    1.2.2 Specification – Type 4524-W-001 - Triaxial General Characteristics Accelerometer Type IEPE – triaxial Voltage Sensitivity (at 159.2 Hz) 100 mV/g Sensitivity Tolerance ±5% on the whole frequency range Measuring Range ±50 g pk Output Full Scale Voltage ±5 V Amplitude Response ±5% from 2 Hz to 2 kHz Phase Response...
  • Page 9 Dielectric Strength 500 Vdc Signal Ground Isolated from housing Connection Through a quadrifilar cable (Double-shielded recommended. Single-shielded possible if connected to structure in both ends.) Environmental Characteristics Temperature Normal Operational Range – 45°C to +125°C Max operating sinusoidal vibration 50 g pk Max.
  • Page 10: Testing

    Ambient temperature: 25°C ±5°C Procedure 2.3.1 Appearance Check labelling. Check overall dimensions. Check electrical connections. Note: For Type 4511-W-006, see for specification of overall dimensions • Fig. 2 For Type 4524-W-001, see for specification of overall dimensions • Fig. 4 2.3.2...
  • Page 11 Mounting the transducer on the calibrator: Start the calibrator by pressing its button. The level displayed / recorded by the DMAU must be: Type 4511-W-006 – : 10 mV (accelerometer sensitivity × 10 ms × gain of DMAU) ± 8% •...
  • Page 12: Electrical Test

    Process: Disconnect the cable of the transducer. Dismount the transducer. Connect the transducer to the CCLD Power Supply cable: For Type 4511-W-006 – , use CCLD Power Supply WB-1372 and the cable supplied with it. Monoaxial For Type 4524-W.001 - , use CCLD Power Supply WB-1453 and the cable supplied with it.
  • Page 13: Disassembly

    Section 3 Disassembly The transducer must not be disassembled or attempted to repair. If there is a problem, contact your Brüel & Kjær representative who may replace the transducer. BN1100 Revision: 0 Initial Issue: 21/08/2012 ATA 31-10-04 The document reference is online, please check the correspondence between the online documentation and the printed version.
  • Page 14: Standard And Special Tools

    Section 4 Standard and Special Tools Standard Tools Standard tools are used for removal/installation and connecting/disconnecting. 14 of 18 The document reference is online, please check the correspondence between the online documentation and the printed version.
  • Page 15: Special Tools

    Special Tools 4.2.1 References of special tools: The following special tools are available: Name Part Number WB -1453 Electrical testing of Type 4524-W -001 CCLD Power Supply WB -1372 Electrical testing of Type 4511-W -006 –W L3429/AO0526/JJ81 (included with Connect W B-1453 to Type 4524-W -001 CCLD Power Supply) not shown Cable...
  • Page 16: 4.2.2 Control Of Special Tools

    4.2.2 Control of special tools : -Manufacturer control: CCLD Power Supply WB-1372 and WB-1453 and Calibration Exciter Type 4294 must be sent to Brüel & Kjaer every two (2) years for certification of their specifications. -On site Control of the CCLD power Supply WB1372 and WB1453: Press the switch in battery position.
  • Page 17: Consumables

    Section 5 Consumables 9 V batteries 6 LR61 for CCLD Power Supply WB-1372, WB-1453 and Calibration Exciter Type 4294. BN1100 Revision: 0 Initial Issue: 21/08/2012 ATA 31-10-04 The document reference is online, please check the correspondence between the online documentation and the printed version.
  • Page 18: Cleaning, Storage And Transportation

    Section 6 Cleaning, Storage and Transportation Clean the accelerometer with a dry smooth cloth. Store the equipment in a polythene bag, then in a cardboard box. When the unit is packed as above, it must be stored in clean, dry, well-ventilated premises free from corrosive fumes. The temperature should be between –40 to +70°C and relative humidity between 20% and 85%.