Specification - Haier HPU-42CV03 Service Manual

Hide thumbs Also See for HPU-42CV03:
Table of Contents

Advertisement

2. SPECIFICATION

item
Function
Capacity
Capacity
Sensible heat ratio
Total power input
Max. power input
EER or COP
Dehumidifying capacity
Power cable
Signal cable
Connecting cable
Wired control cable
Power source
Running /Max.Running current
Start Current
Class of anti electric shock
Circuit breaker
Max. operating pressure of heat side
Max. operating pressure of cold side
Unit model (color)
Fan
Heat exchanger
Dimension
Air sending angle
Drainage pipe (material , I.D./O.D.)
Control type
(Remote /wired /model)
Fresh air hole dimension
Outlet distribution hole dimension
Electricity Heater
Noise level
(H-M-L)
Weight
(Net / Shipping)
Dimension
Weight
(Net / Shipping)
Unit model (color)
Compressor
Fan
Heat exchanger
Dimension
Drainage pipe (material , I.D./O.D.)
Refrigerant control method
Defrosting
Volume of Accumulator
Noise level
Type of Four way valve
material of reduce noise
crankcase heater power
Weight
(Net / Shipping)
Refrigerant
Pipe
Connecting Method
Between I.D &O.D
Norminal condition: indoor temperature (cooling): 27℃DB/19℃WB, indoor temperature (heating): 20℃DB
Outdoor temperature(cooling): 35℃DB/24℃WB, outdoor temperature(heating): 7℃DB/6℃WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a sound pressure noise level.
The detailed method please refer to the following information:
Commercial Air Conditioner
Model
for wired control unit
Type × Number
Speed(H-M-L)
Fan motor output power
Air-flow(H-M-L)
Type / Diameter
Total Area
Temp. scope
External
(L×W×H)
Package
(L×W×H)
External
(L×W×H)
Package
(L×W×H)
Model / Manufacture
Oil model
Oil type
Oil charging
Type
Protection type
Starting method
Type × Number
Speed
Fan motor output power
Air-flow(H-M-L)
Type / Diameter
Row / Fin pitch
Temp. scope
External
(L×W×H)
Package
(L×W×H)
Type / Charge
Recharge quantity
Liquid
Gas
MAX.Drop
MAX.Piping length
cooling
BTU/h
41000
12.0
kW
70%
3700
W
W
4400
3.24
W/W
10‐³×m³/h
section
section
section
section
/
N, V, Hz
Cooling 6.9A/7.8A Heating 7.0/8.3
A / A
A
CLASS I
A
2.8
Mpa
Mpa
2.8
r/min
kW
m³/h
mm
mm×mm×mm
mm×mm×mm
mm
mm
mm
kW
dB(A)
kg / kg
mm×mm×mm
mm×mm×mm
kg / kg
VR54KS-TFP-542/COPELAND
Inner thermal protection
r/min
kW
m³/h
mm
mm×mm×mm
mm×mm×mm
mm
mm/mm
L
dB(A)
W
kg / kg
g
g/m
mm
mm
m
m
Model: HPU-42CV03
HPU-42HV03
HPU-42CV03
heating
----
----
----
----
----
5.0
2
5G×2.5mm
2
4G×0.75mm
/
3N,380-400V,50HZ
50
----
20
----
----
HPU-42CV03(WHITE)
centrifugal
430/405/370
0.09
1750
inner grooved/φ7
0.45
1850×600×350
1980×660×420
Remote
/
/
51
59/70
/
/
/
HPU-42CV03(WHITE)
3GS
1360
SCROLL
hard startup
Axial*2
840
0.06
6000
inner grooved/φ9.52
2/1.6
948*340*1250
1090*410*1350
Capillary tube
Automatic
/
59
/
/
/
106/111
R22/3400
65
φ9.52
φ19.05
Flared
30
50

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hpu-42hv03

Table of Contents