Download Print this page

3onedata IPMC101 Series Quick Installation Manual page 2

Industrial

Advertisement

Step 1
Check if the DIN-Rail mounting kit is installed firmly.
Step 2
Insert the bottom of DIN-Rail mounting kit (one side
with spring support) into DIN-Rail, and then insert
the top into DIN-Rail.
Tips:
Insert a little to the bottom, lift upward and then insert
to the top.
Step 3
Check and confirm the product is firmly installed on
DIN-Rail, then mounting ends.
【Disassembling DIN-Rail】
Step 1
Device power off.
Step 2
After lift the device upward slightly, first shift out the
top of DIN-Rail mounting kit, then shift out the
bottom of DIN-Rail, disassembling ends.
Note before powering on:
Power ON operation: first connect power line to the
connection terminal of device power supply, then power
on.
Power OFF operation: first unpin the power plug, then
remove the power line, please note the operation order
above.
【Power Supply Connection】
DC power supply
This device provides 3-pin 7.62mm pitch terminal blocks. This
power supply supports anti-reverse connection.
Power supply range: 48VDC (44~55VDC).
【DIP Switch Setting】
Provide 4-bits DIP switch for function setting,
where "ON" is enable valid terminal.
The definitions of DIP switch are as follows:
No.
Definition
Operation
1
Flow control
Set the switch to ON
2
Jumbo frame
Set the switch to ON
3
LFP alarm
Set the switch to ON
4
Reserved
-
【Checking LED Indicator】
The device provides LED indicators to monitor its operating
status, which has simplified the overall troubleshooting
process. The function of each LED is described in the table as
below:
LED
Status
Description
PWR is connected and running
ON
normally
PWR
PWR is disconnected and running
OFF
abnormally
ON/OFF
Device runs abnormally
RUN
Blinking
Device runs normally
ON
POE port is powering other devices
PoE
OFF
POE port is not powering other devices
Copper port has established valid
ON
connection
Copper port is in an active network
Blinking
1
status
Copper port hasn't established valid
OFF
connection
Fiber port has established valid
ON
connection
2
Blinking
Fiber port is in an active network status
OFF
Fiber port hasn't established valid
connection
Fiber/copper port is not connected or
ON
connected abnormally
LFP
Fiber/copper port is connected
OFF
normally
【Specification】
Panel
100M copper port
10Base-T/100Base-TX
self-adaption
100M fiber port
100Base-FX, optional SFP or
SC/ST/FC interface
PoE
Maximum power of PoE port:
30W
PoE power supply pin: V+, V+,
V-, V- correspond to 1, 2, 3, 6
Indicator
Power supply indicator, remote
alarm
indicator,
connection
copper port connection status
indicator, running indicator
S
witch property
100M forwarding speed
148810pps
Buffer size
1K
MAC address
2K
Power supply
Input power supply
DC power supply 48VDC
Support anti-reverse protection
Access terminal
3-pin 7.62mm pitch terminal
blocks
Power consumption
Model I
No-load: 1.63W@48VDC
Full-load: 18.39W@48VDC
Model Il
No-load: 1.97W@48VDC
Full-load: 18.62W@48VDC
Operating
environment
Operating temperature
-40~75℃
fiber
port
status
indicator,

Advertisement

loading

This manual is also suitable for:

Ipmc101-f-poeIpmc101-1s-poe