7. Once the RJ45 cable(s) are attached, align the pins on the rear panel of the access point with the slots on
the mounting bracket. Press the button on the bottom of the mounting bracket and slide the access point
into the bracket. Release the button to secure the access point to the mounting bracket, as shown in
Figure
Figure 4 Securing the access point to the mounting bracket
8. To lock the access point to the mounting bracket, insert the T6 Torx security screw into the hole beside
the button, located at the bottom of the mount, then tighten the screw until it is snug.
9. After the access point is securely fastened to the mounting bracket, connect the Ethernet cable(s) to the
appropriate RJ45 coupler port(s) on either side of the mount.
Installing the Mount Housing onto a Wall Box
1. Align the holes on the mounting bracket with the corresponding holes on the wall box. To install this kit
to a single gang wall box, refer to
Figure
holes indicated.
Figure 5 Installing the mounting bracket to a single-gang wall box
AP-220-MNT-W3
| Installation Guide
4.
6. Then, using the 10mm machine screws, fasten the mount housing to the wall box using the
Figure
5. To install this mount kit to a dual gang wall box, refer to
3