FBD120/180/200/220 SECTIONAL GARAGE DOOR OPENER
P2. Adjusting Obstruction Force Sensitivity
If the door meets an obstruction during closing, it will stop and reverse about
15cm~20cm.
1. Press and hold "SET" button for 4 seconds until 'P1' is displayed on LED.
2. Press "UP" button, 'P2' will be displayed.
3. Press the "SET" button, the opener is now in force adjustment mode.
4. Press "UP" button to increase force setting, maximum force setting is level 9 (F9).
Press "DOWN" button to decrease force, minimum force setting is level 1(F1).
5. Press "SET" button to confirm the setting.
NOTE:
Regularly check the obstruction force and make sure it is working correctly, and is TESTED
•
(by placing a 50mm high object on the floor) Failure to follow the manual could result in
serious personal injury and/or property damage.
Photo electric beam must be used for all installations where the closing force as measured
•
on the bottom of the door is over 400 N (40 kg). Installers should ensure that the doors are
installed in a compliant manner as per AS/NZS 60335-2-95.
Press the "SET" button, the opener
is now in force adjustment mode.
Press "SET" button to confirm the
setting
SET
Press and hold "SET" button
for 4 seconds until 'P1' is
displayed
SET
SET
(Fig.14)
Press "UP" button, 'P2'
will be displayed.
Press "UP" button to increase
force setting, maximum force
setting is level 9 (F9). Press
"DOWN" button to decrease
force, minimum force setting
is level 1(F1)
Fig.14
13
SET
SET