7. Programming

Once the opener is connected to power, the number "88" will be displayed on the LED.
And ' . ' indicates the opener is now on normal status.

P1. Open and Close Limit

1. Press and hold "SET" button for 4 seconds until 'P1' is displayed.
2. Press "SET" again, 'OP' will be displayed.
3. To set open limit, Press and hold "UP" button, 'OP' on the LED display will be flashing,
release the button until the door has reached desired position.
4. Press "SET" to confirm the open limit position. the LED will now indicated the 'CL'.
5. To set close limit, press and hold "DOWN" button, 'CL' will be flashing, release the button
until the door has reached desired position.
6. Press SET to confirm the close limit position.
7. Limit setting complete.
NOTE:
Photo electric beam must be used for all installations where the closing force as measured
on the bottom of the door is over 400 N (40 kg). Installers should ensure that the doors are
installed in a compliant manner as per AS/NZS 60335-2-95.