Automatic control switch 2 standard

Advertisement

System 2000
Automatic control switch 2 Standard
Product characteristics
-
Extension of the detection area in combination with the 3-wire extension insert
-
Operation with 2-wire extension or installation button
-
Teach function for adjustment of the brightness threshold
-
Switch-on brightness permanently storable, with dimming insert
-
Light dimmable, with dimming insert and connected 2-wire extension insert
-
Creep zone protection
-
Run-on time limit
i Sensitivity and run-on time cannot be changed.
Automatic operation
The motion detector detects heat motions of people, animals and objects.
-
The light is switched on when the detection area is entered and the brightness threshold is
exceeded.
The run-on time restarts with each detected motion.
-
The light is switched off if no motion is detected in the detection area and the run-on time
has elapsed or the run-on time limit is reached.
To avoid any light swings caused by a cooling illuminant, the motion detector does not evaluate
any motion signals for a brief lockout time after switching off. The motion detector adjusts itself
to the ambient conditions to keep the time as short as possible.
The day/night switchover takes place after a delay of 30 seconds. Switching over is thus
prevented by briefly illuminating or shadowing to the day/night operation.
Run-on time limit
The light is switched off after 90 minutes at the latest even if there is constant motion in the
detection area. The light is only switched on again if the brightness drops below the threshold
and motions are detected.
Behaviour after a mains failure
-
Less than 0.2 seconds: The old switching position is restored after mains return.
-
0.2 seconds until approx. 2 seconds: The light is switched on for the run-on time after
mains return.
-
Longer than 2 seconds: The motion detector goes through a self-test for approx. 40
seconds after mains return. The light is first switched on. After approx. 10 seconds, the
light is switched off. After the end of the self-test, the light is switched on for the duration of
the run-on time.

4 Operation

Switching on light for the duration of the run-on time
A 2-wire extension or an installation button is connected.
o
Press 2-wire extension or installation button for less than 0.4 seconds.
Light is switched on depending on brightness and motion. Motions are evaluated further
and prolong the run-on time.
i If the motion detector is combined with a dimmer insert, the light is always switched on to
the saved switch-on brightness
i The light cannot be switched off manually.
Adjust the brightness
Motion detector is combined with a dimming insert.
The light can be dimmed temporarily. The next time the light is switched on, it is switched on
again to the switch-on brightness
A 2-wire extension is connected.
Light is switched on.
o
2-wire extension above, press for longer than 0.4 seconds.
The light gets brighter up to maximum brightness.
o
2-wire extension below, press for longer than 0.4 seconds.
32576902
10410709 I00
12.01.2012
2/7