Instructions
Danfoss inverter compressors
VZH028-VZH065
VZH028-044
Operating limits
VZH028-044 operating map - R410A (SH 6 K)
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
-40
-35
VZH052-065 operating map - R410A (SH 6 K)
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
-35
-30
All the above limits, temperatures and speeds, are secured by parameters in the drive and
application controller softwares.
Installation and servicing of the compressor by qualified personnel only. Follow these instructions and sound refrigeration engineering
practice relating to installation, commissioning, maintenance and service.
The compressor must only be
used for its designed purpose(s)
and within its scope of application
(refer to «operating limits»). Consult
Application guidelines and datasheet
available from cc.danfoss.com
- Depending on the frequency converter
version, the physical position of individual
connectors may differ from below diagram.
- Always make sure that the compressor
terminals T1, T2, T3 are connected to the
frequency converter terminals 96, 97, 98
respectively.
© Danfoss | DCS (CC) | 2019.03
A
B
C
D
A: Model number
B: Serial Number
C: Refrigerant
D: Manufacturing year
E: Supply voltage range
F: Max operating current
G: Lubricant type and nominal charge
VZH052-065
Voltage: 400-460V/208-230V
40-100 rps
60-100 rps
30-100 rps
15-100 rps
-30
-25
-20
-15
-10
-5
0
5
Evaporating temperature (°C)
4200-6000rpm
2400-6000rpm
1800-6600rpm
1000-6600rpm
-25
-20
-15
-10
-5
0
5
10
Evaporating temperature (°C)
Never operate
c o m p r e s s o r
without terminal
box cover in place
and secured.
- The compressor motor cable must be shielded
and the armoured part must be connected to
ground on both cable ends; at the side of the
compressor and at the side of the frequency
converter.
- Use an EMC cable gland for cable installation and
perfect grounding; The metallic terminal box of
20-100 rps
10
15
20
25
VZH67F Map
Solid line bondaries:
SH=6K
Dash line bondaries:
need ensure Tdis
<135°C
15
20
25
30
Under all circumstances,
the EN378 (or other applicable
local safety regulation)
requirements must be fulfilled.
Wear protective goggles and
work gloves.
Basic connections
Electrical connections
E
F
G
Quick connect
Ring connect screw terminals
spade terminals
VZH028-044
push
push
VZH028 - VZH065 compressors can be
powered by the dedicated variable speed
drive or third party drive.
When Danfoss drive is selected, check carefully
for compatibility between compressor model
and variable speed drive.
Compressor
model
VZH028-J/G
VZH035-J/G
VZH044-J/G
VZH028-H
VZH035-H
VZH044-H
VZH052-J
VZH065-J
VZH052-G
VZH065-G
VZH052-H
VZH065-H
Note : These instructions replace instructions
in grommet kit.
The compressor must
The compressor is delivered under
be
handled
with
nitrogen gas pressure (between
caution in the vertical
0.3 and 0.4 bar / 4 and 6 psi). Do
position
(maximum
not disassemble bolts, plugs,
offset
from
the
fittings, etc... unless all pressure
vertical : 15°).
has been relieved from the
compressor.
the compressor has a paint-free surface around
the connection hole for better conductivity.
- A low pressure safety switch is mandatory
to avoid compressor vacuum operation.
- At start-up, verify that the compressor rotates
in the right direction and pumps.
AN233086441027en-000201 | 1
C & Q terminal box type
VZH052-065
push
Driver
Driver
power
model
6kW
CDS803
7.5kW
CDS803
10kW
CDS803
7.5kW
CDS303
11kW
CDS303
11kW
CDS303
11kW
CDS303
11kW
CDS303
11kW
CDS303
15kW
CDS303
15kW
CDS303
22kW
CDS303

Advertisement

loading

Summary of Contents for Danfoss VZH028 Series

  • Page 1 20-100 rps VZH028 - VZH065 compressors can be powered by the dedicated variable speed drive or third party drive. 15-100 rps When Danfoss drive is selected, check carefully for compatibility between compressor model and variable speed drive. Compressor Driver Driver Evaporating temperature (°C)
  • Page 2 0 - 10 V control Frequency converter in slave mode Sensor Process loop: preset on input 54 4 - 20 mA control External Frequency converter under own PID controller Load / Relay © Danfoss | DCS (CC) | 2019.03 2 | AN233086441027en-000201...
  • Page 3 Frequency converter in slave mode Sensor can be selected by changing parameters in the «Quick menu». Process loop: External 4 - 20 mA control Load / Relay Frequency converter under own PID controller © Danfoss | DCS (CC) | 2019.03 AN233086441027en-000201 | 3...
  • Page 4 3.6 kg, For VZH052-064, the refrigerant charge between high side and low side 36 bar limit is 5.4 kg. Above this limit; protect the of the compressor compressor against liquid flood-back with a © Danfoss | DCS (CC) | 2019.03 4 | AN233086441027en-000201...
  • Page 5 • Check the compressor current draw by reading suitable company at its site. means of measuring the return gas superheat one of the parameters via Modbus. © Danfoss | DCS (CC) | 2019.03 AN233086441027en-000201 | 5...
  • Page 6 Denmark Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trade- marks in this material are property of the respective companies.

This manual is also suitable for:

Vzh044 seriesVzh052 seriesVzh065 seriesVzh028-jVzh028-gVzh035-j ... Show all