White Rodgers 1F92W-51 Installation & Operation Manual page 29

White-rodgers installation & operation guide multi-stage/heat pump electronic digital thermostat 1f92w-51
Table of Contents

Advertisement

affect thermostat operation. Replace the bat-
tery, re-program the thermostat if necessary,
put the thermostat back on the wall, and use
SYSTEM
to set thermostat for desired opera-
HEAT-OFF-COOL-AUTO
tion. To set the thermostat for automatic
changeover after programming, press
to set the thermostat to AUTO (the setpoint
display is blank in the AUTO mode). The sys-
tem will now automatically switch between heat-
ing and cooling depending on the actual room
temperature.
79
COOLING TEMPERATURES
78
77
DEAD BAND 1°F
76
75
HEATING TEMPERATURES
74
73
AUTOMATIC CHANGEOVER (ON)
Switch #1 set at installation (DO NOT CHANGE)
Switch #2 set at installation (DO NOT CHANGE)
SYSTEM
HEAT-OFF-COOL-AUTO
Switch #3 set at installation (DO NOT CHANGE)
Switch #4 ON
In the AUTO mode, the thermostat will not allow the
temperature separation between the highest heat
setting and the lowest cool setting to be less that 1 F.
For example, if the highest heat setting is 76 F, the
lowest cool setting cannot be below 77 F (see
diagram at left).
ON
1
2
3
4
NOTE
29