1F90W-71 OPERATION GUIDE 5 Day/2 Day Electronic Digital Thermostat WHITE-RODGERS W H I T E - R O D G E R Operator: Save this booklet for future use!
About Your New Thermostat . . . Your new White-Rodgers Digital Thermostat uses the technology of a solid-state microcomputer to provide precise time/temperature control. This thermostat offers you the flexibility to design heating and cooling programs that fit your needs. Please read this manual thoroughly before operating or programming your thermostat.
Page 3
YOUR NEW THERMOSTAT'S FEATURES ... 4 OPERATING YOUR THERMOSTAT ... 5 PARTS OF THE THERMOSTAT The Back Of the Thermostat Body The Display The Thermostat Buttons OPERATING FEATURES In This Guide . . . PROGRAMMING YOUR THERMOSTAT ... 19 PLANNING FOR YOUR NEEDS ENTERING YOUR PROGRAM Set Current Time and Day Enter Heating Program...
YOUR NEW THERMOSTAT’S FEATURES • Separate 5-day (weekday) and 2-day (week- end) setback programming • Simultaneous heat and cool program stor- • Four separate time/temperature settings per 24-hour period • Computed Energy Management Recovery (EMR) • Automatic changeover (operator-selectable) • Armchair programming capability •...
OPERATING YOUR THERMOSTAT Before you begin programming your thermo- stat, you should be familiar with its features and with the display and the location and operation of the thermostat buttons. The information in this section will help you become familiar with your new thermostat so that you can easily program it.
these, then gently pivot the thermostat body down to connect the three pin connectors on the lower portion of the thermostat back. Gently push until the snap connectors engage. DO NOT FORCE OR PRY THE THERMOSTAT, as this may damage the unit. PARTS OF THE THERMOSTAT The Back of The Thermostat Body Turn the thermostat body over.
Page 7
2. You may adjust the option switches for keypad lockout, limited temperature range, and automatic changeover from heat to cool (see OPERATING FEATURES). Other than located behind the thermostat door. To open the door, pull the door out from the top, then swing it down on its hinges.
Page 8
The Display Continuously displays system mode (HEAT, OFF, COOL, AUTO, HOLD). During pro- gramming, the program period is displayed (MOR, DAY, EVE, or NHT). Alternately displays room temperature (F denotes degrees Fahrenheit and C denotes degrees Celsius) and time of day (A de- notes AM time and P denotes PM time).
Page 9
5 DAY FAN AUTO TIME SYSTEM HEAT-OFF-COOL-AUTO TIME BACK - AUTO 2 DAY FAN AUTO 5 DAY VIEW HOLD CLOCK PRGM TEMP PRGM PRGM FAN ON BATTERY...
Page 10
The Thermostat Buttons Sets the system mode (HEATing, OFF, COOLing, or AUTOmatic changeover). Selects fan operation (see #6, above). This button is also used to program the fan to run continuously during a program period. Runs display forward or backward through time, day, or anticipation settings during programming.
Page 11
5 DAY FAN AUTO TIME SYSTEM HEAT-OFF-COOL-AUTO TIME BACK - AUTO 10 11 12 13 14 15 VIEW HOLD CLOCK PRGM TEMP PRGM PRGM...
OPERATING FEATURES Now that you are familiar with the thermostat display and buttons, read the following informa- tion to learn about the many features of the thermostat. • COMPUTED ENERGY MANAGEMENT RECOVERY (EMR) — The thermostat’s microcomputer can be set to automatically calculate the time it will take to change the temperature to the next program setting.
Page 13
use a pencil or small screwdriver to move the switch to the OFF position (see figure below). Leave the battery out of the thermo- stat for at least two minutes, to allow the thermostat to reset itself. See AUTOMATIC CHANGEOVER to determine proper posi- tions of Group B option switches #1 and #2.
Page 14
utes, to allow the thermostat to reset itself. Replace the battery, reprogram the thermo- stat, if necessary, put the thermostat back on the wall, and restore 24v AC power. To set the thermostat for automatic changeover after programming, press thermostat to AUTO (the setpoint tempera- ture display is blank in the AUTO mode).
Page 15
display shows the temperature you want. The thermostat will override current pro- gramming and keep the room temperature at the selected temperature for two hours. After two hours, the thermostat will auto- matically revert to the program. • HOLD TEMPERATURE — The thermostat can hold any temperature within its range for an indefinite period, without reverting to HOLD...
Page 16
(long cycles), you may want to adjust the anticipation setting. CAUTION A cooling anticipation setting of less than 10 may cause decreased compressor life. To adjust heat anticipation, press at the same time. The display will show HEAT 5 (this is the factory prepro- grammed heating anticipation setting).
Page 17
be replaced. The word BATTERY will be displayed continuously (non-flashing) when 24v AC power is not being supplied to the thermostat and the thermostat is operating on battery power only. • AUDIO PROMPTING — Each time you press a button, the thermostat will beep. •...
Page 18
Total Keypad Lockout Group A Option Switches Switch #1 ON Switch #2 OFF To enable total keypad lockout, move Group A option switch #1 to ON (see figure above). To disable total keypad lockout, move op- tion switch #1 to OFF. •...
PROGRAMMING YOUR THERMOSTAT Now you are ready to program your thermostat. This section will help you plan your thermostat's program to meet your needs. For maximum comfort and efficiency, keep the following guidelines in mind when planning your program. • When heating (cooling) your building, pro- gram the temperatures to be cooler (warmer) when the building is vacant or during peri- ods of low activity.
Page 20
2a. What time do the building occupants reach a maximum activity level (using lights, equip- ment, meeting rooms, etc.)? b. What temperature should the building be at this time? These will be your DAY tempera- ture settings. 3a. What time do the building occupants reach a minimum activity level (limited personnel in building)? b.
Page 21
b. What temperature should the house be at this time? These will be your NHT (night) temperature settings. Now look at the factory preprogrammed times and temperatures shown on the following page. If this program will suit your needs, simply press to begin running the factory preset pro- PRGM gram.
Determine the time periods and heating and cooling temperatures for your weekday pro- gram. You must program 4 periods for each day (MOR, DAY, EVE, and NHT). However, you may use the same heating and cooling tempera- tures for consecutive time periods. You can choose start times, heating temperatures, and cooling temperatures independently for both weekday and weekend programs (for example,...
Page 23
Heating/Cooling Schedule Plan WEEKEND (2 DAY) WEEKDAY (5 DAY) Start Start Time Temperature Time Temperature MOR HEAT DAY HEAT EVE HEAT NHT HEAT MOR COOL DAY COOL EVE COOL NHT COOL...
Page 24
MOR HEAT DAY HEAT EVE HEAT NHT HEAT MOR COOL DAY COOL EVE COOL NHT COOL SAMPLE Heating/Cooling Schedule Plan WEEKEND (2 DAY) WEEKDAY (5 DAY) Start Time Temperature 5:30 AM 68°F 7:00 AM 8:00 AM 65°F 11:00 AM 5:00 PM 70°F 6:00 PM 10:30 PM...
Page 25
Set Current Time and Day 1. Press once. The display will show CLOCK minutes only. EXAMPLE: 2. Press and hold either you reach the correct minutes. 3. Press once. The display window will CLOCK show the hour only. EXAMPLE: 4. Press and hold either you reach the correct hour and AM/PM designation (AM begins at midnight;...
Page 26
VIEW until you are at the point where you PRGM stopped programming. Then you may continue to enter your programs normally. If you want to stop programming at any time, simply press to resume program operation. PRGM SYSTEM 1. Press until HEAT is displayed.
Page 27
VIEW 6. Press . The currently programmed PRGM start time and heating temperature for week- day DAY will be displayed. 7. Repeat steps 3 through 5 to select the start time and heating temperature for the week- day DAY program. 8.
SYSTEM 1. Press until COOL appears. HEAT-OFF-COOL-AUTO 2. Follow the procedure for entering your heat- ing program, using your selected cooling times and temperatures. CHECK YOUR PROGRAMMING Follow these steps to check your thermostat programming one final time before beginning thermostat operation.
Press until FAN AUTO is displayed – AUTO (automatic cycling). QUESTIONS AND ANSWERS 1. How can I permanently change a part of my program? VIEW Press until you reach the time/tem- PRGM perature schedule you want. Then press TIME TIME BACK change the program.
Page 30
VIEW programming, press PRGM to the point where you stopped program- ming. Then you may continue to program the thermostat normally. If you want to stop programming at this point, press start the normal program function. See PROGRAMMING YOUR THERMOSTAT. 4.
Page 31
During periods of low humidity (especially during cold weather), you may feel or see a spark discharge when you touch the ther- mostat. This may cause the program to be lost or the thermostat to display incorrectly. To correct this, remove the thermostat from the wall and disconnect the battery.
Page 32
8. The display is flashing BATTERY. What does this mean? The "AA" batteries installed in the thermo- stat are low and should be replaced with ® fresh "AA" Energizer alkaline batteries. See OPERATING YOUR THERMOSTAT. 9. The display shows a continuous (non- flashing) BATTERY.
Page 33
sons. • The EMR function is operating. The EMR function will automatically bring on the system automatically to bring the temperature to the selected level by the beginning of the next program period. See OPERATING YOUR THERMO- STAT. • You have programmed the incorrect day or time.
Page 34
14. Between heating and cooling seasons, I want to turn my system off. Can I do this without affecting my thermostat pro- gramming? Any time you wish to turn your system off, SYSTEM simply press until the display shows HEAT-OFF-COOL-AUTO OFF.
Page 35
batteries installed or if the installed batteries are dead. If you are changing the batteries after seeing a flashing BATTERY on the display, the installed batteries may be dead. If you remove the old batteries and install fresh ones within one minute, you should not lose your thermostat programming.
Page 36
If you need further information on programming or operation, write to: White-Rodgers Division, Emerson Electric Co. 9797 Reavis Road St. Louis, MO 63123 Attn: Technical Service Department Part No. 37-5088A 9139...