Default Parameter; Reading Operating Parameters; Reading Version Number; Reset Instruction - Ebyte E64 Series User Manual

Uart
Table of Contents

Advertisement

Wireless UART Module
3
C2+ working parameters
4
C3+C3+C3
5
C4+C4+C4

7.1 Default Parameter

Model
network NO.
E64-T100S2
0x00

7.2 Reading Operating Parameters

Instruction format
C1+C1+C1

7.3 Reading Version Number

Instruction format
C3+C3+C3

7.4 Reset Instruction

Instruction format
C4+C4+C4

7.5 Parameter Setting Instruction

The difference between C0 command and C2 command is that C0 command will write parameters into the internal flash memory and can
be saved when power down, while C2 command cannot be saved when power down, because C2 command is temporarily mend
instruction.C2 is recommended for the occasion that need to change the operating parameters frequently, such as C0 00 00 18 03 44.
No.
Item
0
HEAD
Fix 0xC0 or 0xC2, it means this frame data is control
command.
1
NC
Reserved
2
NC
Reserved
3
SPED
Rate parameter, including UART baud rate and air
7,6:
Copyright ©2012–2017, Chengdu Ebyte Electronic Technology Co., Ltd.
C2 + 5 bytes working parameters are sent in hexadecimal format. 6 bytes in total and must be
sent in succession. ( Do not save the parameters when power-down )
Three C3 are sent in hexadecimal format. The module returns the version information and they
must be sent in succession.
Three C4 are sent in hexadecimal format. The module will reset one time and they must be sent
in succession.
Slave address
0x00
In instruction mode(M0=0,M1=1) ,
User gives the module instruction (HEX format): C1 C1 C1,
Module returns the present configuration parameters.
For example, C0 00 00 18 00 44.
In instruction mode(M0=0,M1=1),
User gives the module instruction (HEX format): C3 C3 C3,
Module returns its present version number, for example C3 64 xx yy.
64 here means the module model (E64 series); xx is the version number and yy refers to the other module features.
In sleep mode(M0=1,M1=1),
User gives the module instruction (HEX format): C4 C4 C4, the module resets for one time.
During the reset process, the module will conduct self-check, AUX outputs low level. After reset completing,
the AUX outputs high level, then the module starts to work regularly which the working mode can be switched
or be given another instruction.
Description
date rate
UART parity bit
00:8N1(default)
01:8O1
10:8E1
Default parameter values:C0 00 00 18 00 40
Air data rate
Baud rate
8kbps
9600
Description
Description
Description
l
C0: Save the parameters when power-down
C2: Do not save the parameters when power-down
N/A
N/A
l
User Manual of E64 Series Modules
Parity
Transmitting power
8N1
100mW
Notes
Must be 0xC0 or 0xC2
UART
mode
can
be
communication parties
FEC
Enable
different