Yamaha RX-V377 Series Service Manual page 33

Hide thumbs Also See for RX-V377 Series:
Table of Contents

Advertisement

2-4.
When the protection function worked due to
excessive heatsink temperature.
TMPxPRT:xxxL
Cause: The temperature of the heatsink is excessive.
Supplementary information: The protection function
worked due to the temperature limit being exceeded.
Causes could be poor ventilation or a defect related to
the thermal sensor.
Turning on the power without correcting the abnormality
will cause the protection function to work in 1 seconds
and the power supply will be shut off.
● History of protection function
When the protection function has worked, its history
is stored in memory as backup data.
Even if no abnormality is noted while servicing the
unit, an abnormality which has occurred previously
can be defined as long as the backup data has
been stored.
For details, refer to "P2. PROTECTION HISTORY"
menu.
2-4.
H: Displayed when the voltage is HIGHER than upper limit
電圧が上限値より高い場合に表示されます
L: Displayed when the voltage is LOWER than lower limit
電圧が下限値より低い場合に表示されます
xxx: A/D conversion value of voltage at the moment when the protection function worked
(Reference voltage: 3.3 V=255)
プロテクションが働いた瞬間の電圧の A/D 変換値
(基準電圧:3.3 V=255)
TMP1/TMP2/TMP3
原因: ヒートシンクの温度が異常。
補足: 温度制限を越えた原因で、プロテクションが働い
異常状態のまま電源を入れると、1 秒後にプロテクション
が働き、電源が切れます。
● プロテクションの履歴
ヒートシンクの異常温度によりプロテクション
が働いた場合
たことを示します。
プロテクションが働いた場合、その履歴はバック
アップデータとしてメモリーに保存されます。
修理のときに異常が認められなくても、バックアッ
プデータが残っていれば、お客様のところで起きた
異常を区別できます。
詳 細 は、"P2. PROTECTION HISTORY" メ ニ ュ ー を
参照してください。
RX-V377/HTR-3067
33

Advertisement

Table of Contents
loading

Table of Contents