TRACEABLE® DIGITAL DIAL THERMOMETER INSTRUCTIONS

SPECIFICATIONS:

Display:
/
" LCD
3
8
Range:
–67.0 to 300.0 °F / –55.0 to 149.0 °C
Resolution:
0.1°
Accuracy:
Cat. No. 4042 ±1.8°F
Cat. No. 4044 ±1.0°C
Cat. No. 4342 ±0.4°F
Cat. No. 4344 ±0.2°C
Sampling Rate: 10 seconds
Features:
No on/off switch (operates continuously for 1-1/2 years on a single, replaceable silver
oxide battery), stainless steel probe, and protective plastic sleeve.

OPERATION

1. To activate the thermometer pull out the plastic tab from the battery compartment.
2. Remove the protective plastic sleeve of the thermometer probe and insert the probe into the material
to be measured.
3. The temperature reading is updated every ten seconds.
4. The clip-loop on the end of the sleeve may serve as a thermometer holder when the thermometer is
removed from the sleeve.

ALL OPERATIONAL DIFFICULTIES

If this unit does not function properly for any reason, replace the battery with a new high-quality battery
(see "Battery Replacement" section). Low battery power can occasionally cause any number of "appar-
ent" operational difficulties. Replacing the battery with a new fresh battery will solve most difficulties.

BATTERY REPLACEMENT

Erratic readings, a faint display, or no display, are all indicators that the battery must be replaced. Use a
screwdriver and remove the battery cap by turning the cap counterclockwise approximately a quarter of
a turn. Turning the cap further than a quarter of a turn may damage the cap. Replace exhausted battery
with a new 1.5 volt battery. Make certain the positive (+) side is face up. Replace the battery cover cap.
Do not overtighten the cap. Replacement battery Cat. No. 4032.
Cat. No. 4042 / 4044 / 4342 / 4344
Traceable® Digital Dial Thermometer Instructions
92-4344-00
Rev. 2 062404
©
2004

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4344 and is the answer not in the manual?

Questions and answers

Summary of Contents for Traceable 4344

  • Page 1 1.5 volt battery. Make certain the positive (+) side is face up. Replace the battery cover cap. Do not overtighten the cap. Replacement battery Cat. No. 4032. Cat. No. 4042 / 4044 / 4342 / 4344 Traceable® Digital Dial Thermometer Instructions 92-4344-00 Rev.
  • Page 2 For more information, please contact us: ExpotechUSA 10700 Rockley Road Houston, Texas 77099 281-496-0900 [voice] 281-496-0400 [fax] E-mail: sales@expotechusa.com Website: www.ExpotechUSA.com...

Table of Contents