Optional Items; Tkre01; Tk-Bk01; Tk-Tv01 - Takagi T-K1S Installation Manual And Owner's Manual

Instantaneous water heater
Table of Contents

Advertisement

1. TKRE01emperature Remote Controller
°F, and it also works as a diagnostic tool that will
give a concise error code whenever there is a
problem with the unit. The temperature options
are 95°F, 100°F, 102°F, 104°F, 106°F, 108°F,
109°F, 111°F, 113°F, 115°F, 117°F, 122°F,
131°F, 140°F, 158°F, and 167°F. See the trouble
shooting section for information on possible error
codes.
3. TK-TV01 Vent Terminator
This terminator can be used
where a T-K1S is going to be
vented out through a wall. This
is a CSA approved part of the
unit. Connect a Category III
Stainless vent pipe from the
top of the unit to the backside of this terminator to
exhaust flue gases through the wall without a
thimble. Install vent terminator in accordance with
manufacturer's installation instructions and any
applicable local codes.

Optional Items

The

TKRE01

temperature
Remote
Controller
has
two
functions, it allows the
output
temperature
from the T-K1S to be
adjusted
within
the
range of 95 °F to 167
5. TK-BK01 Wall Mounting Brackets
The TK-BK01 Wall Mounting Brackets allow the T-K1S to be installed
hanging from a wall. It is not necessary to earthquake strap these
heaters if these brackets are used. If the unit is not going to be
mounted on a wall, the "L" brackets that are included with every unit
will be sufficient as earthquake protection. Install unit and brackets
according to
manufacturer's
applicable codes.
20
3. TK-TV03 Vent Damper
unit. This helps prevent harmful exhaust gases
from entering the home, as well as helping to
prevent the units from freezing in areas where
cold air can be blown into the exhaust system.
Install vent damper according to manufacturer's
installation instruction, and any applicable codes.
4. TK-TV03 Vent Cap
The TK-TV03 Vent Cap is for
outdoor installation with the
T-K1S water heater. The cap
is installed on the top of the
unit, instead of connecting an
exhaust vent. The cap will
prevent any debris that might
be in the environment from entering the unit and
causing damage or a fire hazard, as well as
preventing rain or other weather from entering the
unit.
installation
The TK-TV03 Vent
Damper prevents the
backflow
of
air
through the exhaust
vent. This is CSA
approved part of the
instructions
and
any

Hide quick links:

Advertisement

Table of Contents
loading