PS6010 Hardware Maintenance
Control modules are installed vertically in the array, with the latch mechanism
facing the adjacent power supply and cooling module. See Figure 3-4.
Figure 3-4: Correct Control Module Orientation
To install a control module:
1. Attach an electrostatic wrist strap or a similar protective device. See Using an
Electrostatic Wrist Strap on page 1-5.
1. Open the control module latches by squeezing together the release mechanism
for each latch and then rotating each latch outwards. See Figure 3-2.
2. Correctly orient the control module with the latch mechanism facing the
adjacent power supply and cooling module.
3. Hold the latches and slide the control module into the slot until you feel
resistance. See Figure 3-5.
Maintaining Control Modules
3–9