• Do not exceed max. operating pressure or operating temperature range (see data
label).
• The permissible working temperatures and pressures for ad-on parts and tower
elements are given under Technical data for those ad-ons. Maximum temperature
and pressure for assembled system is the lowest of any individual part.
• It is necessary to ensure that the unit is equipped with the corresponding safety and
test devices to prevent the permissible operating parameters from being exceeded.
• Tower has been designed for a primarily static pressure. Rapid changes of pressure
are not allowed.
• Ensure that the tower is not subject to vibrations that could cause fatigue fractures.
• Tower is not to be subjected to mechanical stresses.
• The medium used may not have any corrosive components that could attack the
materials of the tower in a way that is not permitted. Do not use the adsorber in
hazardous areas with potentially explosive atmospheres.
• All installation and maintenance work on the tower may only be carried out by
trained and experienced specialists.
• It is forbidden to carry out any kind of work on the tower and piping, including
welding and constructional changes, etc.
• A pressure gauge, which shows the operational pressure, must be installed in the
unit, respectively in the pipeline.
• Depressurize the system before carrying out the installation work. The unit must be
installed vertically in the piping.
• Ensure that tower is installed without any stresses.
• Use original spare parts only.
• Use the device for appropriate purpose only.

Appropriate use

TACm series adsorbers are designed for high efficient removal of oil vapours from
compressed air and vacuum systems. This appliance must be used only for the
purpose for which it was specifically designed. All other uses are to be considered
incorrect and will void warranty.
Specifically:
tower can only be used for "GROUPE 2" fluids (PED 2014/68/EU).
tower can not be used for explosive, toxic, flammable, corrosive and "GROUPE 1"
fluids (PED 2014/68/EU).
Warning: internal corrosion can seriously reduce the safety of installation: check it during
changing the activated carbon.