Download Print this page

Christie DLV1400-DX Instruction Sheet page 4

Lamp and filter replacement
Hide thumbs Also See for DLV1400-DX:

Advertisement

Install the Lamp Module
1. Verify that the lamp memory board - located on the rear left of the lamp - is not obstructed. If it is
covered with a plastic protector, remove it before installing the lamp. Failure to do this will
hamper the proper installation of the lamp and prevent normal operation.
2. Record the serial number of the new lamp.
3. Align the new lamp with the top and bottom guides on the left side of the lamp compartment. Slide
the lamp all the way in – a slightly harder push may be required right at the end to make sure the
lamp is fully seated into the terminal block.
NOTE: The lamp module must make full contact with the terminal block. The projector will not
power up again if the lamp is not fully connected to the terminal block.
4. Pull and turn the locking lever clockwise to 3 o'clock to secure the lamp module.
NOTE: If the locking lever cannot be easily turned, then the lamp is not fully inserted.
5. Install the lamp door and secure (2) #2 Phillips® self retaining screws.
6. Plug in and power on the projector and navigate to the lamp menu. Select CHANGE LAMP. This
will prompt for the old lamp serial number (if it was not previously entered). Enter the new lamp
serial number.
NOTE: This action is not mandatory, it is recommended for accurate lamp statistics to be
archived. If you neglect to enter a serial number, the lamp times will not reset to "0" and will
therefore be inaccurate, in which case, the lamp life limit will expire prematurely.
4 of 6
Lamp and Filter Replacement Instruction Sheet
020-100160-02 Rev. 1 (01-2012)