Download Print this page

Manifold Installation - Nimbus Water Systems Sierra Manual

Reverse osmosis drinking water system
Hide thumbs Also See for Sierra:

Advertisement

Manifold Installation

Determine the most practical under-the-sink location for placement of the Sierra manifold unit and the companion
reservoir tank. Ensure that the specifi c location allows adequate access to the manifold unit for cartridge re-
placement and to the tank for tank- valve operation.
1. Place the manifold and tank in the selected locations. If desired, the #6 self tapping screws may be used to
secure the manifold unit in position by means of the top rear and bottom lip mounting holes.
2. Take the unused portion of the 3/8" white tubing and insert one end fi rmly into the 3/8" (largest) connector on
the top of the manifold unit.
3. Extend the 3/8" white tubing from the manifold unit to the tank valve. Leave enough slack in the tubing to allow
the unit to be removed from the installed location for servicing. Cut off the excess and insert the 3/8" tube into the
quick-connect tank valve fi tting until it is fully engaged.
4. Extend the 1/4" yellow tubing from the faucet unit to the manifold. Leave enough slack in the tubing to allow
the unit to be removed from the installed location for servicing. Cut off the excess and fi rmly insert the tubing into
the corresponding yellow drain connection located on the manifold.
5. Extend the 3/8" blue tubing from the faucet unit to the manifold. Leave enough slack in the tubing to allow the
unit to be removed from the installed location for servicing. Cut off the excess and fi rmly insert the tubing into the
corresponding blue product water connection located on the manifold.
6. Extend the green tubing from the feed connector valve to the manifold. Leave enough slack in the tubing to al-
low the unit to be removed from the installed location for servicing. Cut off the excess and fi rmly insert the tubing
into the corresponding green feed connection located on the manifold.
7. Obtain the Shutoff Warning label and affi x it to the manifold unit so that it is directly visible. The Sierra system is
now connected and ready for initial test and preparation.
TUBING HINTS:
Use a sharp knife or tubing cutter to cut the tubing squarely, being sure to remove all burrs.
Then insert the tubing fi rmly until it stops. To remove the tubing, push against the collet while pulling on the tubing.
41840-A McAlby Court, Murrieta, CA 92562
8
(800) 451-9343, www.nimbuswater.com

Advertisement

loading