6.2
Monthly inspection work to be carried out by the operating
company
The monthly inspection and maintenance of individual components by the operator requires little time
and serves the reliable function, increased service life and operational safety of the installation.
Test / inspection
Sensors and LED strips
BAL_FlowControl_EN_1V2_REC_121-006454644
Servicing and maintenance
Procedure
▪ Walk towards the door at
normal speed (from the insi-
de and outside).
▪ If necessary, clean the sen-
sors and LED strips.
▪ Please note: Moisture con-
densation on the sensor, due
to the escape of warm, moist
internal air and condensation
on the colder external motion
sensor, can prevent the door
from closing. Dehumidify the
interior air or wipe the outer
sensor dry if necessary.
Expected result
▪ The sensor must cover the
entire passage width.
▪ LED strips indicate the cor-
rect status.
▪ The door is opened at an
early stage and at an approp-
riate speed to allow unhin-
dered passage.