Under Sink Heating Tank Installation Instructions and Use and Care Guide

ELECTRICAL REQUIREMENTS

A 120-volt, 60-Hz, 15-amp, grounded electrical supply is
required. It is recommended that a separate circuit serving only
your Heating Tank be provided. Use an outlet that cannot be
turned on/off by a switch. If the supply cord is damaged, it must
be replaced in order to avoid a hazard.

RECOMMENDED GROUND METHOD

The heating tank must be grounded. This appliance is equipped
with a power supply cord with a 3 prong ground plug. To minimize
possible shock hazard, the cord must be plugged into a mating, 3
prong, ground-type outlet, grounded in accordance with all
national and local codes and ordinances. If a mating outlet is not
available, it is the personal responsibility and obligation of the
customer to have a properly grounded, 3 prong outlet installed by
a qualified electrician. If codes permit and a separate ground wire
is used, it is recommended that a qualified electrician determine
that the ground path is adequate.

LOCATION REQUIREMENTS

Determine where the heating tank and all components being used in the installation should be
mounted beforehand and make sure there is adequate clearance for plumbing and electrical
components and there is enough tubing to reach the intended mounting positions. For best
performance, position the heating tank to allow a 4" space around the top and sides. Do not put
any objects on top of the heating tank.