Troubleshooting Chart; California Proposition - Wayne WAPC250 Quick Start Instructions

Auto on-off water removal pool cover pump
Table of Contents

Advertisement

Available languages

Available languages

MAINTENANCE (CON'T)
6. Check the priming hole for obstruction. (Figure 1).
Follow the cleaning steps listed below:
a. Disconnect pump from power source.
b. Remove the strainer.
c. Remove the four (4) base screws (Figure 1).
d. Remove the base and impeller plate.
e. Use a pin or paperclip to clean the priming hole and
air escape channel.
f. Reinstall impeller plate, base, screws and strainer.
7. If pump runs continuously, unplug the unit. Once
unplugged, remove the strainer and check for debris
stuck inside the sensor body (Figure 2). Remove any
trapped leaves, debris or dirt.
Figure 2 - Remove Debris From Sensor
8. If the pump cycles on and off too often the electronic switch may
need cleaning. Disconnect pump from power source, remove
the strainer and turn the pump upside down. The sensor probe
Troubleshooting
Chart
Symptom
Possible Cause(s)
Pump will not
1. Tripped home electrical breaker
start or run
2. GFCI tripped
3. Low line voltage
4. Defective motor
5. Dirty switch
6. Impeller obstructed
7. Inlet screen or strainer clogged
8. Priming hole plugged
Pump starts and
1. Backflow of water from piping
stops too often
2. Dirty switch
3. Priming hole plugged
4. Pump is sitting uneven on pool or spa
cover
Pump will not
1. Debris in switch
shut off or runs
2. Discharge height exceeds capability
continuously

CALIFORNIA PROPOSITION 65

This product or its power cord may contain chemicals, including lead, known to the State of California to cause cancer and birth defects
or other reproductive harm. Wash hands after handling.
CLEAN DEBRIS
INSIDE SENSOR
BODY
SENSOR PROBE
Electrocution Hazard! Pump starts automatically. Disconnect the power before
attempting any repairs. Failure to follow WILL result in serious injury or death.
Corrective Action
1. Reset breaker
2. Check for damaged wiring or moisture
3. Contact electrician
4. Replace pump
5. Rinse out switch with clean water (Figure 2)
6. Remove strainer, base, and impeller plate (Figure1) check for debris;
clean
7. Clean inlet screen and debris strainer (Figure 1)
8. Clean hole, inside volute housing, with a pin or paper clip (Figure 1)
1. Install or replace check valve
2. Rinse out switch with clean water (Figure 2)
3. Clean hole, inside volute housing, with a pin or paper clip (Figure 1)
4. Reposition pump so pump sits level on cover
1. Rinse out switch with clean water (Figure 2)
2. Reduce discharge height
5
will be visible inside the switch housing. Clean inside the housing
gently scrubbing with a small brush using soapy water. Then rinse
thoroughly with clean water.
9. When temperatures drop below freezing remove pump from
service and store indoors to protect pump from damage due
to ice. The pump has a unique protection circuit to protect
the motor from a locked impeller condition possibly caused
by debris buildup or from a "frozen" impeller situation caused
by ice formation. When the pump is activated and a locked
impeller condition is detected the unit will automatically
shutdown to protect the motor from overheating. The pump
will continue this on/off cycle for a period of time to attempt to
"free" the impeller until eventually the unit will remain off for a
period of 12 hours checking twice a day for a "freed" impeller.
Once the pump is able to operate correctly the pump will
Do NOT use pump if any part of the switch
housing or probe is cracked, broken or missing.
PUMPING HEIGHT
When water is pumped to an elevated position, any volume
that has not reached the discharge outlet can flow back
through the pump when the pump shuts off. This back-flow
can cause the water level in small areas to rise enough to
re-start the pump. The check valve/hose adapter included is
required in this situation. For proper operation, make certain
the check valve is oriented as instructed on check valve body.
In small areas a check valve is required to prevent
backflow. Without a check valve the pump may cycle
continuously and potentially wear out the pump components.
WAPC250
www.waynepumps.com

Advertisement

Table of Contents
loading