With a TORX (TX10) screwdriver unscrew the right had
side screw underneath the warranty seal.
With a TORX (TX10) screwdriver, unscrew the left hand
screw near the AC input connector.
Pull out the panel to extract the voltage change system
with the corresponding cables.
With pliers, remove all the numbered cables from the
panel. Do not pull the cables to disconnect the
connector.
At this point you should find the panel as in the
picture. Now you are ready to set the AC input voltage
of the amplifier.

Advertisement

loading

Summary of Contents for RM Italy BLA-600

  • Page 1 RM Italy BLA-600 Disassembly Procedure With a TORX (TX10) screwdriver unscrew the right had side screw underneath the warranty seal. With a TORX (TX10) screwdriver, unscrew the left hand screw near the AC input connector. Pull out the panel to extract the voltage change system with the corresponding cables.
  • Page 2 RM Italy BLA-600 115V Setup At this point you should find the panel as in the photo. Now you are ready to set the AC input voltage of the amplifier. Connect cable "1" to one of the spade lugs labelled "A"...
  • Page 3 RM Italy BLA-600 230V Setup At this point you should find the panel as in the photo. Now you are ready to set the AC input voltage of the amplifier. Connect cable "1" to one of the spade lugs labelled "A"...
  • Page 4 RM Italy BLA-600 240V Setup At this point you should find the panel as in the photo. Now you are ready to set the AC input voltage of the amplifier. Connect cable "1" to one of the spade lugs labelled "A"...
  • Page 5 230 Vac Supply 6A 240 Vac Supply 5A RM Italy BLA-600 Input Voltage Set Up and Voltage/Fuse Information Courtesy of DX Engineering - 16 August 2018 DX Engineering - 1200 Southeast Ave. - Tallmadge, OH 44278 USA - Phone 800-777-0703...