Connection, Installation / Mounting; Requirements For The Electrician - Busch-Jaeger Busch-AudioWorld 8216 U Busch-Radio iNet Product Manual

Table of Contents

Advertisement

6

Connection, installation / mounting

Danger - Electric voltage!
Risk of death due to electrical voltage of 100 ... 240 V during short-circuit in the
low-voltage conduit.
Caution! - WLAN signal is too weak!
If the WLAN signal is too weak at the mounting location planned for the device,
the device cannot be commissioned later.
6.1

Requirements for the electrician

Danger - Electric voltage!
Install the device only if you have the necessary electrical engineering
knowledge and experience.
The minimum necessary expert knowledge and requirements for the installation
are as follows:
Product manual 2CKA001473B8724
Low-voltage and 100 ... 240 V conduits must not be installed together in a
flush-mounted box!
Before starting work with a WLAN-capable device, check whether the WLAN
signal is strong enough at the location planned for the installation of the
device.
If in doubt, select a different mounting location.
Incorrect installation endangers your life and that of the user of the electrical
system.
Incorrect installation can cause serious damage to property, e.g. due to fire.
Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1. Disconnect
2. Secure against being re-connected
3. Ensure there is no voltage
4. Connect to earth and short-circuit
5. Cover or barricade adjacent live parts.
Use suitable personal protective clothing.
Use only suitable tools and measuring devices.
Check the type of supply network (TN system, IT system, TT system) to
secure the following power supply conditions (classic connection to ground,
protective earthing, necessary additional measures, etc.).
Connection, installation / mounting