Receiver Alignment; Sensitivity - Yaesu FTM-2001 Operating Manual

Table of Contents

Advertisement

III. RECEIVER
Assemble the test equipment as shown at the right.
A . Sensitivity
1. Set the transceiver to channel 120, and the
RF generator to 160.100 MHz.
2. Set the RF generator output level to 40dBu
with ±3.5 kHz déviation o f a 1 kHz modu-
lating tone.
3. Adjust T201 - T205 on the Mother Board
for minimum deflection on the déviation
meter (less than -4dBu).
4. Confirm a 12dB S1NAD o f -4dB or better
on channels 122 and 159.
RECEIVER SECTION ALIGNMENT POINTS