Specifications − High-Static M3 Chassis - LG MULTI V ARNU073M1A4 Installation Manual

Ducted indoor units
Table of Contents

Advertisement

GENERAL DATA
Specifications − High-Static M3 Chassis
Table 5: Ducted High Static M3 Chassis Indoor Unit General Data.
Model No.
Cooling Mode Performance
Capacity (Btu/h)
Max Power Input
(W)
1
L/M/H Power Input at Factory Default (W)
Heating Mode Performance
Capacity (Btu/h)
Max Power Input
(W)
1
L/M/H Power Input at Factory Default (W)
Entering Mixed Air
Cooling Max. (°F WB)
Heating Min. (°F DB)
2
Unit Data
Refrigerant Type
3
Refrigerant Control
Sound Power
dB(A) (H/M/L@0.24" ESP)
4
Net Unit Weight (lbs.)
Shipping Weight (lbs.)
Communication Cable
(No. x AWG)
5
Fan
Type
Motor
Housing
Motor/Drive
Airflow Rate H/M/L (CFM)
Standard Mode
Airflow Rate H/M/L (CFM)
High Mode (Factory Set)
External Static Pressure (in. wg)
Standard Mode
External Static Pressure (in. wg)
High Mode (Factory Set)
Piping
Liquid Line (in., O.D.)
Vapor Line (in., O.D.)
Condensate Line (in., I.D.)
EEV: Electronic Expansion Valve
Power wiring is field supplied and must comply with the applicable local and national
codes.
This unit comes with a dry nitrogen charge.
All capacities are net with a combination ratio between 95-105%.
Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change
without notice. Current certified ratings are available at www.ahridirectory.org.
Max. power input is rated at maximum setting value.
1
Low ambient performance with LGRED° heat technology is included in Multi V 5 Air
2
16
ARNU283M3A4
ARNU363M3A4
28,000
36,200
650
650
60 / 83 / 109
75 / 107 / 161
31,500
40,600
650
650
60 / 83 / 109
75 / 107 / 161
76
59
R410A
R410A
EEV
EEV
64 / 62 / 61
65 / 63 / 61
96.1
96.1
110.0
110.0
2 x 18
2 x 18
Sirocco
Sirocco
1
2
1,235 / 1,060 / 915
1,327 / 1,097 / 952
1,250 / 1,017 / 837
1,449 / 1,191 / 918
0.19
0.19
0.23
0.23
3/8 Flare
3/8 Flare
5/8 Flare
5/8 Flare
1
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
ARNU423M3A4
42,000
650
75 / 107 / 161
47,000
650
75 / 107 / 161
76
76
59
59
R410A
EEV
65 / 63 / 61
96.1
110.0
2 x 18
Sirocco
1
1
2
2
Brushless Digitally Controlled / Direct
1,327 / 1,097 / 952
1,449 / 1,191 / 918
0.19
0.23
3/8 Flare
5/8 Flare
1
1
Source Units produced after February 2019.
Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or
3
destroy R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F)
under section 608 of CAA.
Sound Power level is measured using rated conditions and tested in a reverberation room
4
per ISO 3741 standards.
All communication cable to be minimum 18 AWG, 2-conductor, twisted, stranded, shielded
5
and must comply with applicable local and national codes. Shield must be joined and
insulated throughout. Ensure the communication cable is properly grounded at the master
outdoor unit only.
Do not ground the ODU-IDU communication cable at any other point.
ARNU483M3A4
ARNU543M3A4
48,100
54,000
650
650
75 / 107 / 172
172 / 215 / 260
54,200
61,400
650
650
75 / 107 / 172
172 / 215 / 260
76
76
59
59
R410A
R410A
EEV
EEV
67 / 64 / 62
69 / 68 / 67
96.1
96.1
110.0
110.0
2 x 18
2 x 18
Sirocco
Sirocco
1
1
2
2
1,720 / 1,558 /
1,457 / 1,189 / 952
1,424
1,744 / 1,614 /
1,482 / 1,191 / 918
1,482
0.19
0.19
0.23
0.23
3/8 Flare
3/8 Flare
5/8 Flare
5/8 Flare
1
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents