EDI SSM-LE Series Operation Manual

Nema ts-1 enhanced signal monitor
Table of Contents

Advertisement

SSM-LE Series
NEMA TS-1
Enhanced Signal Monitor
Operations Manual
THIS MANUAL CONTAINS TECHNICAL INFORMATION FOR THE SSM-6LE, SSM-
6LEip, SSM-6LEC, SSM-12LE, SSM-12LEip, and SSM-12LEC SERIES SIGNAL
MONITOR.
REVISION: MARCH 2012
pn 888-1216-002

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SSM-LE Series and is the answer not in the manual?

Questions and answers

Summary of Contents for EDI SSM-LE Series

  • Page 1 SSM-LE Series NEMA TS-1 Enhanced Signal Monitor Operations Manual THIS MANUAL CONTAINS TECHNICAL INFORMATION FOR THE SSM-6LE, SSM- 6LEip, SSM-6LEC, SSM-12LE, SSM-12LEip, and SSM-12LEC SERIES SIGNAL MONITOR. REVISION: MARCH 2012 pn 888-1216-002...
  • Page 2 THE SSM-LE SERIES SIGNAL MONITOR IS DESIGNED AND MANUFACTURED IN THE USA BY EBERLE DESIGN INC. PHOENIX, ARIZONA EDI IS CERTIFIED TO ISO 9001:2008 QUALITY SYSTEMS STANDARDS. INFORMATION CONTAINED HEREIN IS PROPRIETARY TECHNICAL INFORMATION OF EBERLE DESIGN INC. PUBLICATION, REPRODUCTION OR USE IN WHOLE OR PART IS NOT PERMITTED EXCEPT UNDER TERMS AGREED UPON IN WRITING.
  • Page 3: Table Of Contents

    3.11.1 Basic FYA MODE ..................11 3.11.2 Compact FYAc MODE ................12 3.11.3 FYA Channel Assignment Diagrams ............13 Section 4 ECcom Interface .....................14 4.1 EDI ECcom Monitor Reports .................14 4.1.1 General Data ....................14 4.1.2 Current Status (S) ..................14 4.1.3 Previous Fault (PF) Event Log ..............14 4.1.4 AC Line (AC) Event Log ................14...
  • Page 4 5.3 SSM Switch Programming ..................16 5.4 Unit Option Programming ..................17 5.4.1 GY ENABLE Option ..................17 ® 5.4.2 LEDguard Enable Option ................17 5.4.3 External Watchdog Enable Option ...............17 5.4.4 Walk Disable Option..................17 5.4.5 Controller Voltage Monitor (CVM) Latch Programming .........17 5.4.6 24VDC Monitor Latch Programming .............17 5.4.7 Log CVM FAULTS Option ................17 5.4.8 Flashing Yellow Arrow Monitor ..............17 Section 6 Front Panel Description ..................18...
  • Page 5 8.3 EIA-232 Connector ....................27 8.3.1 EIA-232 Cable to a PC .................28 8.4 Ethernet LAN Port ....................28 8.4.1 Ethernet LAN Cable ..................28...
  • Page 6: Section 1 General

    The SSM-LE Series Signal Monitor is a device used in a Traffic Controller Assembly to accomplish the detection of, and response to improper and conflicting signals and improper operating voltages in a Controller Assembly caused by malfunctions of the Controller Unit (CU), load switches, or mis-wiring of the cabinet.
  • Page 7: Flashing Yellow Arrow (Fya) Protected-Permissive Movement

    The loss of AC LINE will not reset the fault mode of the OUTPUT relay contacts. In the event of AC LINE loss the SSM-LE Series will retain the status of all fault and channel indicators and will display the correct fault and channel status upon restoration of AC LINE.
  • Page 8: Ledguard Led Field Signal Sensing

    LED FIELD SIGNAL SENSING ® The Eberle Design SSM-LE Series can be configured to use a technique called LEDguard that is designed to better monitor the characteristics of LED based signal loads (See Section 5.4.2). Each field signal input is measured and compared to both a high threshold and a low threshold value to determine On / Off status.
  • Page 9: Section 2 Standard Nema Functions

    OUTPUT relay contacts to the Fault position, and display the RED FAIL status screen. The SSM-LE Series will remain in the fault mode until the unit is reset by the RESET button or the EXTERNAL RESET input. When voltages on all inputs to a channel are sensed as inactive for less than the Red Fail No-Fault time, the SSM-LE Series will not transfer the OUTPUT relay contacts to the Fault position.
  • Page 10: 24Vdc Monitor Inhibit Input

    OUTPUT relay when the True (low) state is restored to the input. The SSM-LE Series will remain in the fault mode for at least the time determined by the Minimum Flash programming. A CVM failure during the programmed Minimum Flash time or during a Power Failure will not cause a fault condition.
  • Page 11 AC LINE voltage is sufficient for proper operation. The SSM-LE Series should be the first component in the cabinet to sense a low voltage condition and the last component to sense a proper AC LINE operating voltage.
  • Page 12: Section 3 Enhanced Features

    AC Line power. This EEPROM device requires no battery back-up. The time of day in the SSM-LE Series is stored in a battery-backed real time clock circuit. Should this battery fail, only current time of day and date information will be lost. No monitor configuration programming is stored under battery power.
  • Page 13: Gy Enable Option

    SSM-LE Series will enter the fault mode, transfer the OUTPUT relay contacts to the Fault position, and display the CLEARANCE status screen. The SSM-LE Series will remain in the fault mode until the unit is reset by the RESET button or the EXTERNAL RESET input.
  • Page 14: Reset Input Detection

    Operations Manual and display the PROGRAM CARD status screen. The SSM-LE Series will remain in the fault mode until the Program Card is correctly seated and the SSM-LE Series is reset by the RESET button or the EXTERNAL RESET input.
  • Page 15: Flashing Yellow Arrow Protected-Permissive Monitoring (Fya)

    Pulse detection algorithm will process these pulses into one event and trigger a Conflict fault once the longer recurrent timing threshold is exceeded. When triggered by a recurrent pulse fault condition, the SSM-LE Series will enter the fault mode, transfer the Output relay contacts to the Fault position, and display the appropriate CONFLICT, DUAL INDICATION, or RED FAIL status screen along with RP STATUS.
  • Page 16: Basic Fya Mode

    Series associates channel 1 with 9, channel 3 with 10, channel 5 with 11, and channel 7 with 12 when FYA monitoring is enabled for that respective approach. If a channel pair is enabled for FYA operation, the SSM-LE Series will monitor the FYA logical channel pair for the following fault conditions:...
  • Page 17: Compact Fyac Mode

    (re)wired such that the outputs of the Ped Yellow load switches are monitored by channels 9, 10, 11, and 12 Green. If a channel pair is enabled for FYAc operation, the SSM-LE Series will monitor the FYA logical channel pair for the following fault conditions: Conflict i.
  • Page 18: Fya Channel Assignment Diagrams

    SSM-LE Series Operations Manual A Clearance fault will be detected if the FYAc channel pair sequences from the solid Green Arrow (9, 10, 11, 12) to the solid Red Arrow (1, 3, 5, 7) without a minimum clearance time on the solid Yellow Arrow (1, 3, 5, 7).
  • Page 19: Section 4 Eccom Interface

    The EDI ECcom software package (Version 3.6.8 or greater is required) interfaces a Computer or System to the SSM-LE Series. The ECcom program will display the Status (S), Previous Fault (PF) event log, AC Line (AC) event log, Manual Reset (MR) event log, Configuration (CF) event log, and Signal Sequence logs.
  • Page 20: Configuration (Cf) Event Log

    4.1.7 SIGNAL SEQUENCE EVENT LOG The Signal Sequence event log graphically displays all signal states and Red Enable state for up 30 seconds prior to the SSM-LE Series fault trigger for the most recent five (5) Previous Fault (PF) events.
  • Page 21: Section 5 Installation

    Series will enter the fault mode, transfer the OUTPUT relay contacts to the Fault position, and display the PROGRAM CARD status screen. The SSM-LE Series will remain in the fault mode until the Program Card is correctly seated and the SSM-LE Series is reset by the RESET button or the EXTERNAL RESET input.
  • Page 22: Unit Option Programming

    SSM-LE Series Operations Manual The channel SSM switch should be placed in the ON position when a channel has a Red, a Yellow, and a Green signal that turn both On and Off. The channel SSM switch should be placed in the OFF position when an unused Red field output terminal is connected to AC+ or for a channel that does not monitor the Yellow input such as an exclusive Ped channel.
  • Page 23: Section 6 Front Panel Description

    SSM-LE Series Operations Manual Section 6 Front Panel Description 6.1 FAULT STATUS DISPLAY CVM/WD 24V-1 24V-2 The Fault Status Display is a wide temperature CONFLICT DUAL INDICATION range Liquid Crystal Display (LCD) as shown. RED FAIL PROGRAM CARD SSM-LE series...
  • Page 24: Clearance Indicator

    Operations Manual 6.1.9 CLEARANCE INDICATOR The CLEARANCE indicator will be illuminated on the SSM-LE series Signal Monitor when no Yellow or a short (less than 2.7 seconds) Yellow signal is detected on a channel(s) during a Red to Green to Yellow to Red sequence. The Field Status display will show all active field output signals at the time of the Clearance fault.
  • Page 25: Fault Indicator

    6.4 BUTTONS 6.4.1 RESET BUTTON Depressing the RESET button resets the SSM-LE series Signal Monitor after it has been triggered by a fault. The monitor remains in the reset mode only if the fault condition has been restored to normal. Depressing the RESET Button while the display is in the PF Data Log, AC Data Log, or Clock Set mode will only reset the display mode to the normal mode.
  • Page 26: Ac Data Log Display Mode (Ac Data Log)

    SSM-LE Series Operations Manual recent fault event logged. Previous Failure #25 is the oldest fault event logged. If the display indicates PF 0, the Previous Failure event log is empty. 6.5.2 AC DATA LOG DISPLAY MODE (AC DATA LOG) The second closure of the MODE button advances the display mode to the AC Data Log mode.
  • Page 27: Section 7 Specifications

    SSM-LE Series Operations Manual Section 7 Specifications 7.1 ELECTRICAL 7.1.1 POWER REQUIREMENTS Operating Line Voltage ................75 to 135 Vrms Operating Line Frequency ................60 + _ 3Hz Power Consumption ................10W (nominal) 7.1.2 AC VOLTAGE MONITORS Nema Green Signal Inputs No Detect .................
  • Page 28: Timing Functions

    SSM-LE Series Operations Manual LCD Operating Temperature Range ............-34 to +74 Humidity Range (non-condensing) ............. 0 to 95% Relative 7.4 TIMING FUNCTIONS Conflict No Fault .................. less than 200 msec Fault .................. greater than 450 msec Typical ....................350 msec Red Fail No Fault ..................
  • Page 29: Section 8 Wiring Assignments

    SSM-LE Series Operations Manual Section 8 Wiring Assignments 8.1 SSM-12LE HARNESSING CONNECTORS These Military Specification MIL-C-26482 connectors are interchangeable with 12 channel monitors as defined by NEMA Traffic Control Systems Specification TS1-1989 R2005, part 6. Connector MS-A will intermate with a MS 3116 22-55 SZ. Connector MS-B will intermate with a MS 3116 16-26 S.
  • Page 30: Ssm-12Le Connector Ms-B Pin Terminations

    SSM-LE Series Operations Manual Function Channel 1 Yellow Controller Voltage Monitor +24V Monitor Inhibit Output Relay 1 Closed (Stop Time, Opens when fault occurs) Output Relay 2 Open (FTR Drive, Closes when fault occurs) Channel 12 Walk Channel 11 Walk...
  • Page 31: Ssm-6Le Harnessing Connector

    SSM-LE Series Operations Manual Function Start-Delay Relay Closed (Open during Start Delay period) Channel 10 Red Spare 4 Spare 5 Spare 6 Channel 3 Red Red Enable Spare 7 Spare 8 8.2 SSM-6LE HARNESSING CONNECTOR This Military Specification MIL-C-26482 connector is interchangeable with 6 channel monitors as defined by NEMA Traffic Control Systems Specification TS1-1989 R2005, part 6.
  • Page 32 SSM-LE Series Operations Manual Function (Closes when fault occurs) Start Delay Relay Common Channel 6 Yellow Channel 5 Yellow Channel 5 Red Channel 4 Yellow Channel 3 Yellow Channel 3 Red Channel 2 Yellow Channel 1 Yellow Channel 1 Red...
  • Page 33 8.4 ETHERNET LAN PORT The Ethernet port must be configured with specific network parameters such as an IP address and Subnet Mask. The network port parameters are set or changed using the EDI ECcom Signal Monitor Communications software. See the "EDI ECcom Software Operations Manual"...

This manual is also suitable for:

Ssm-6leSsm6leipSsm-6lecSsm-12leSsm-12leipSsm-12lec

Table of Contents