Natural Gas Conversion - Whirlpool W10200946A Installation Instructions Manual

30" (76.0 cm) freestanding gas ranges
Table of Contents

Advertisement

Available languages

Available languages

Natural Gas Conversion

WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
1. Turn manual shutoff valve to the "closed" position.
2. Unplug range or disconnect power.
A
A. To range
B. Manual shutoff valve "closed" position
C. Gas supply line
To Convert Gas Pressure Regulator
1. Open broiler door and remove broiler pan. The gas pressure
regulator is located in the back right hand corner of the broiler
compartment.
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
NOTE: Do not remove the spring beneath the cap.
14
2. Remove the cap from the gas pressure regulator using a
flat-blade screwdriver.
3. Turn the cap over so that N or NAT is visible.
B
4. Reinstall the cap.
C
To Convert Surface Burners
1. Remove burner grate, burner caps and burners.
A
2. Locate the Natural gas orifice spuds for top burners in the
bag containing literature included with the range. Three
Natural gas spuds are stamped "125," one is stamped "132"
and one "128."
3. Remove the LP gas orifice spuds using a 7 mm combination
wrench.
A. Cap
A. Cap
C
A
B
A. Burner cap
B. Burner
C. Center burner
A
A