Download Print this page

Setup Instructions - CAMDEN EMF-2 Installation Instructions Manual

Multi-function timer

Advertisement

Section 3A________________
Set-up Instructions
ABM Vestibule Controller (Mode 1)
The EMF-2 is a compact unit designed to interface an
automatic door operator with a card reader and lock
system such as those used on banks.
When in "Day Mode" the strike is retracted (manually,
or electrically) and the card reader is out of the
circuit. Pressing either exterior or interior wall switch
will activate the door operator.
When the EMF-2 is switched to "Night Mode" the
electric strike is energized (door is locked), and the
exterior activator (ie - wall switch) is removed from
the circuit. When a valid card is inserted, the strike
unlocks immediately, and the exterior switch is put
back into the circuit for an adjustable period, so that if
pushed by the user, it will open the door
automatically. The inside switch will unlock and open
the door at all times.
A new feature of the EMF-2 is the ability to add an
"Emergency - Push-to-Lock" switch near the ATM
machine that when activated "locks out" the card
reader input in order to afford the user extra security.
Opening the door from the inside resets the system.
(The system will also reset automatically after 10
minutes.)
Model EMF-2 ABM provides for a lockable cabinet to
house the relay, c/w two lighted push-button switches
– one to turn the relay power
other to select
or
DAY
NITE
Step 1
Select
via the first 3 positions of the dip
MODE 1
switch as shown below:
See Diagram 1 for location of dipswitch, connectors,
& potentiometers.
Step2
Dip switch Options
Push dipswitch #6
, for a continuous duty strike,
ON
which is to be energized during "Day Mode". If using
an intermittent duty strike and/or the latch is to be
mechanically retracted during "Day Mode", then leave
switch #6
OFF.
Use of Relay 5 is optional, and set according to
dipswitches #4 & 5. (See diagram 1 for location).
IMPORTANT: Any changes Mode selector or
Dipswitches # 7 & 8 have no effect in this mode.
settings must be made with power off!
or
, and the
ON
OFF
modes.
Off On
1
2
3
Out2
Step 3
Connections
Refer to Diagram 2 (next page) for the following
connections.
Wire all input connections to the (removable)
(numbered 1 - 14).
terminal strip
connector if removed.
Next, make your wiring connections to the
(numbered 1 – 15). Note: Relay 4 is not
Output strip
used in this application. Re-insert connector.
If you are using this system with our Model #51T2B
card reader – then refer to the 7-pin
and make wiring connections as per the respective
card-reader wiring diagram.
If using our model #ECI-210, or another type of card
reader, or dry contact - wire to terminals 1 & 2 of the
.
(Re-insert connector firmly if
Digital I/O strip
removed.)
Finally, connect 12 or 24 Volt AC or DC supply to
terminals 1 & 2 of the 2-pin Power Connector.
(The terminals are not polarity sensitive).
Step 4
Adjustments
In this application, you will use pots # 1 – 4. (Pot 5
has no effect.
Timer 1
Strike Delay-on-Release
Timer 2
Operator Delay-on-activate
Timer 3
Operator Delay-on-release
Timer 4
Exterior Switch enable time
Apply power to door operator, EMF-2, and any
applicable activating devices (ie – card-reader).
Observe the
Power LED on the unit. It should be
RED
lit. If not, re-confirm proper voltage connections.
Turn key switch (Input #3) to "Night Mode". (Night
mode via an open contact, Day mode via closed).
Activate interior switch.
open. Adjust potentiometers # 1, 2 & 3 for desired
operating times.
Activate exterior switch. Door should remain closed
and locked. Now activate the card reader input. The
door should unlock. Adjust Timer 1 for sufficient time
on the strike.
When the card reader is activated, the exterior switch
is "put into the circuit" for a limited time. This time is
adjustable from 1 – 30 seconds via pot # 4.
Re-activate the card reader, and within the time
frame, press the exterior switch. The door should
now open.
Input
Firmly re-insert
Relay
Digital I/O strip,
Door should unlock and
Page 3 of 19

Advertisement

loading

This manual is also suitable for:

Emf-2mEmf-2abm