CAMDEN EMF-2 Installation Instructions Manual page 18

Multi-function timer

Advertisement

Dipswitches #7 & 8 are not used in this mode.
IMPORTANT: Any changes to Dip switches,
jumpers, and Mode selector settings must be made
with power off!
Step 3
Connections
Refer to Diagram 8 (page 16) for the following
connections.
Wire all input connections to the (removable)
(numbered 1 - 14).
terminal strip
connector if removed.
NOTE:
Concerning
Magnetic
This system wants to see a Normally Closed
connection when the door is closed. The contact will
then open when the door opens.
configuration will cause the relay to malfunction.
We suggest standard door contacts (ie - Camden
Model # CX-MDC).
Next, make your connections to the
(numbered 1 – 15).
The 7-pin
Digital I/O strip
pins 6 & 7 after 5 minutes of door ajar. If utilizing an
electric floor mat, wire to pins 1 & 2. (This input
should be normally open).
Finally, connect 12 or 24 Volt AC or DC supply to
terminals 1 & 2 of the 2-pin Power Connector.
(The terminals are not polarity sensitive).
Step 4
Adjustments
In this application, you will use pots 1 - 3 & 5. Pot 4
is not used in this mode.
Timer 1
Door lock delay-on-release
Timer 2
Operator delay-on-activate
Timer 3
Operator delay-on-release
Timer 4
Not used
Timer 5
Timer for clearing "walk-aways"
Apply power to door operators, EMF-2, and all
connected equipment (ie – strikes, lights, etc).
Observe the red Power LED on the unit, which
should light. If not, re-confirm proper voltage and/or
terminal strip connection.
Activate an input device to one of the doors.
Observe the respective output LED, which should
light immediately.
The door should unlock and/or
open.
If a request to open comes in from another door while
the first is still open, it will retain the call in memory
until the Door Sense switch indicates the first has
Input
Firmly re-insert
contact
switches.
Any other
relay output strip
provides a trouble output on
closed. If there is a succeeding request on the first
door (or the door that is already opened) it will keep
that door opened.
This memory feature can be
disabled by setting dipswitch #6
Potentiometer #5 is useful if the man-trap utilizes
locks only, and not automatic door operators. Should
a person approach a door and request the door to
unlock, but then change his/her mind and "walk-
away", pot #5 can be set to ignore that request after
an adjustable time. Typically this time would be set
at or close to minimum.
applications it could be set higher (5 – 10 seconds.)
Once the desired operation is achieved, proceed to
Section 4, System Inspection Instructions.
Section 4 _________________
System Inspection Instructions
After the Installation and operational check of the
system:
1. Place warning label on the door (as per ANSI
A156.10 or A156.19 guidelines).
advise the person entering the swing side
zone that the door will move.
2. Instruct the owner on door system operation
and how to test it. This should be checked
on a daily basis.
3. Instruct the owner on what to do if the door or
any of its components become damaged.
4. Strongly recommend to the owner that the
complete entry be inspected twice a year as
part of the service agreement.
ON
For automatic door
This will
Page 18 of 19