Conversion from one gas type to another

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 5
The boiler comes configured for use with methane gas
(G20). It can nevertheless be converted from methane to
LPG (G31) using the kit supplied with the boiler.
b
Note that all modifications to the gas feed system
are forbidden in Belgium. In Belgium, contact r's
Technical Assistance Service.
- Disconnect the electricity supply from the boiler and
shut off the gas cock.
- Remove the top front panel.
- Release the control panel and tilt it forwards.
- Unscrew the nut (A). Move the pipe (B) gently to one
side and replace the diaphragm inside the pipe with the
new diaphragm supplied in the kit.
- Reverse the above steps to reassemble the boiler.
- Switch the electricity supply to the boiler back on and
open the gas cock.
Settings
- - Turn the function selector to OFF/RESET (the display
shows "- -")
- Pull off all 3 control knobs (DHW temperature, function
selector and CH temperature).
- Unscrew the four screws (A) and remove the front trim
(B).
- Adjust the trimmers in the sequence given below to
achieve the values specified in the table.
1 MAX
2 MIN
3 HTG (Max CH)
4 IGN (Burner ignition slow fan speed)
(set to 3.7 = 3700 rpm).
b
Setting changes do not cause the burner to ignite.
As you turn the trimmers, the 2 digit display shows
the current setting value expressed in thousands
(e.g. 2.5 = 2500 rpm).
b
The burner ignition slow fan speed trimmer must
be adjusted after all the other trimmers have been
adjusted.
CONVERSION FROM ONE
GAS TYPE TO ANOTHER
b
Conversions must only be performed by qualified
personnel from r's Technical Assistance Service
or by other personnel authorised by r, even after
the boiler has been installed.
b
On completion of the conversion, adjust the boiler
following the instructions given in the relevant sec-
tion of the manual and apply the new gas label con-
tained in the kit.
2
1
3
0
4
bar
A
B
A
B
A
60
40
80
20
100
0
120
°C
A
A