GDN10AY-K4EBA3A Thank you for choosing our product. For proper operation, please read and keep this manual carefully. If you have lost the Owner’s Manual, please contact the local agent or visit www.gree.com or sent email to global@gree.com.cn for electronic version.
Content Operation Notices ● Operation Area..................1 ● Safety Precautions..................2 ● Parts Name.....................3 ● Check Before Operation.................4 Operation Instructions ● Operation Method...................5 ● Drainage Option..................9 Maintenance ● Clean and Maintenance................11 Malfunction ● Troubleshooting..................13 ● Malfunction Codes................15 This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Page 3
Explanation of Symbols Indicates a hazardous situation that, if not avoided, will DANGER result in death or serious injury. Indicates a hazardous situation that, if not avoided, could WARNING result in death or serious injury. Indicates a hazardous situation that, if not avoided, may CAUTION result in minor or moderate injury.
Operation Area not be used for commercial or industrial applications. enclosed area, such as a closet. temperature will not below 5°C or above 32°C. ● Allow at least 30-45 cm of air space on all sides of the unit. ● Close all doors, windows and other outside openings of the room to improve the working effect.
Safety Precautions ● This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory ormental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the app- liance in a safe way and understand the hazards involved.
Check Before Operation aced. Below are the checking steps: 1. Hold the handles on both sides of the water bucket and pull it out following the arrow direction. moved a little after long-time transportation. If it's not placed properly, move it to the correct position by hand.
Operation Method GDN10AY-K4EBA1A GDN12AY-K4EBA1A Continuous operation GDN10AY-K4EBA3A on indicator light Bucket full light indicates bucket needs to be emptied or it is not in the proper place Smart mode on Running on indicator light indicator light Smart Continuous Full Running...
Page 9
Other Instructions 1. Alarm Warning If bucket is full or not locked into place for over 3min, buzzer will go off for 10s to remind you to empty bucket or put it back into the correct place. 2. Auto Stop When bucket is full, removed or not placed correctly will automatically stop.
Page 10
Basic Functions of the Buttons Running Button operation status all the time. +/- Button Under free drying mode press these buttons to adjust set humidity. Invalid under other modes. ● Pressing + button will increase humidity while pressing - button will decr- ease humidity.
Page 11
Other Instructions 1. Alarm Warning If bucket is full or not locked into place for over 3min, buzzer will go off for 10s to remind you to empty bucket or put it back into the correct place. 2. Auto Stop When bucket is full, removed or not placed correctly or the humidity is 5%lower than the set humidity, unit will automatically stop.
Drainage Option Option 1 Emptying Manually Notes: ● Do not remove the bucket when unit is in operation or has just stopped. ● Do not use the hose if using water bucket to collect water. When the hose is connected, water will be drained out through it instead of into the bucket. 1.
Page 13
Option 2 Gravity Drain Hose 1. Hose is not provided, so user shall prepare it in advance. [Size: The hose should have an inner diameter of 14mm] 2. Remove bucket from the unit as instructed. 3. Thread the drain hose onto the nozzle and make sure it's securely locked.
Clean and Maintenance Warning: may lead to electric shock. Otherwise it will damage unit's appearance. 1. Grille and Case To clean the case: When there is dust on the case, use soft towel to dust it off; When the case is very dirty(greasy), use mild detergent to clean it.
Page 15
Check Before Use-season ● Check whether air outlet is blocked. ● Check whether power plug and power socket are in good condition. ● Check whether drain hose is damaged. Care After Use-season ● Disconnect power. ● Empty the water bucket. Long-time Storage steps below in order to maintain the unit in good condition.
Troubleshooting ● Not all the following problems are malfunctions. Problem Possible Causes ● Unit is operating in an area where temperature is higher than 32°C or lower than 5°C. Controls can not be set. ● Bucket is full. ● Noise will rise if compressor has just started. Noise suddenly rises during ●...
Page 17
GDN10AY-K4EBA1A GDN12AY-K4EBA1A GDN10AY-K4EBA3A Problem Possible Causes Solution ● Check if power is lost. If yes, wait for the power to restore. ● If not, check whether the ● Power is not supplied for power circuit or power socket Power indicator is has been damaged.
● Check whether there is ● Make sure there is no curtain, any obstacle around the shutter or furniture that blocks unit. blocked. ● Make sure all doors and ● Doors and windows are windows and other opening to Bad dehumidifying left open.
Page 19
Display Code Malfunction Unit's Possible Causes Name Condition Display Window ● Temperature sensor on the evaporator is loosen or is poorly connected with the terminal of display board. Tube ● Some element of display board Temperature may have been put upside down Sensor Compressor and cause short circuit.
Page 20
GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 E-mail: gree@gree.com.cn www.gree.com 66160000294...