DYNAFLO ELECTRIC PUMPS
MODELS: 6200, 6210, 6220, 6230
Operating Instructions
WARNING: Failure to follow these instructions and comply with all applicable
codes may cause serious bodily injury and/or property damage.
Prior to using this pump you must ensure that:
• The pump is installed in a safe and dry environment
• The pump enclosure has adequate drainage in the event of leakage
• Any transport plugs are removed
• The pipe-work is correctly sealed and supported
• The pump is primed correctly
• The power supply is correctly connected
• All steps have been taken for safe operation
Appropriate details for all of these items are contained in the following Installation and
Operating Instructions. Read these in their entirety before switching on this pump. If you are
uncertain as to any of these Installation and Operating Instructions please contact your Davey
Dealer or the appropriate Davey office as listed on the back of this document.
WARNING: Some insects, such as small ants, find electrical devices
attractive for various reasons. If your pump enclosure is susceptible to
insect infestation you should implement a suitable pest control plan.
Please pass these instructions on to the operator of this equipment.
Installation and

Advertisement

Table of Contents
loading

Summary of Contents for Davey 6200

  • Page 1 Operating Instructions. Read these in their entirety before switching on this pump. If you are uncertain as to any of these Installation and Operating Instructions please contact your Davey Dealer or the appropriate Davey office as listed on the back of this document.
  • Page 2: Suction Lift

    Dynaflo pump. We urge you to study this publication carefully and follow its recommendations. In the event of installation difficulties or the need for further advice you should contact the Davey Dealer from whom you purchased the unit.
  • Page 3: Suction Piping

    To minimise performance losses we recommend the use of larger diameter pipe. For more detailed advice concerning delivery heads and delivery piping, please consult your local Davey Dealer or the Davey Customer Service Centre on 1300 367 866.
  • Page 4 Single Phase The single phase Models 6200, 6210 & 6220, are supplied with a 10 amp plug or a special 15 amp power plug which may only be used with the appropriate 10 or 15 amp 220/250V power outlet (15 amp power outlets are usually specially provided by an electrician).
  • Page 5 - 5 - A short four core flex (“D”) is fitted from the motor terminals (“E”). This lead is inserted through the Blanking Grommet (“F”). Pressure switch or other control leads (“G”) can be fitted as well. Incoming power (“H”) can be fitted through the preferred access hole, and terminated as shown in Figure Three.
  • Page 6: 10. Trouble Shooting

    Prime should be established almost immediately, however, it may be necessary to re-prime several times on some installations before fully established optimum pump performance is obtained. Do not run pump dry or allow to run continuously in a loss of prime condition.
  • Page 7: 11. Spare Parts

    When ordering spare parts it is essential to give both pump model and motor type numbers from nameplate as well as the full description on part required. *NOTE: For protection, the Davey pump motor is fitted with an automatic reset thermal overload, constant tripping of this overload indicates a problem e.g.
  • Page 8 Customer Service line on 1300 232 839 in Australia, or 0800 654 333 in New Zealand, or send a written letter to Davey at the address listed below. On receipt of your claim, Davey will seek to resolve your difficulties or, if the product is faulty or defective, advise you on how to have your Davey product repaired, obtain a replacement or a refund.