Maintenance; Safety Instructions; General; Lever - ABB RHD Series Service Instruction

Electrical rotary actuator
Table of Contents

Advertisement

8
RHD250 to 4000 (Contrac) ELECTRICAL ROTARY ACTUATOR | SEI/RHD250/4000-EN REV. A

4 Maintenance

Safety instructions

WARNING
Risk of injury due to live parts!
Risk of death or serious injuries due to electricity and
unexpected machine movements. In automatic mode the
motor is always under power, even at standstill.
When working on the actuator or the related subassembly,
switch off the supply voltage for the electronic unit and
separate anti-condensation heater (option), and take
precautions to prevent unintentional switch-on.
Repair and maintenance activities may only be performed by
authorized customer service personnel.
When replacing or repairing individual components, use original
spare parts.

General

Contrac actuators feature a robust construction. As a result,
they are highly reliable and require minimal maintenance. The
maintenance intervals depend upon the effective load and are
therefore not specified here.
The built-in microprocessor evaluates the actual load factors
(e.g. torques, forces, temperatures, etc.) and derives the
remaining operating time until the next routine maintenance is
required.
Use the configuration program to view this information.
Apart from the load dependent maintenance intervals
determined by the microprocessor we recommend routine
maintenance at least every 10 years.
The following description of the maintenance work provide that
the actuator is disconnected from the damper and that all
electrical supply is disconnected.

Lever

Lever removal

Figure 3: Lever mounted on the shaft
Figure 4: Use of draw-off tool for lever removal
In some case it may be useful to detach the linkage bar from the
ball-and-socket-joint, however, it is not absolutely necessary.
Refer to Figure 3 and Figure 4 for the removal procedure:
1. Loosen the clamping screw
2. Use an expanding screw
3. Push a counterpart
3
order to protect the expanding screw thread.
4. Put the claws of the drawing tool
and place the bolt end
5. Put an appropriate tool onto the hexagon end
drawing tool bolt.
6. Turning the bolt clockwise will pull the lever from the
shaft end.
.
2
to spread the lever seat.
1
(soft metal) into the lever gap in
9
behind the lever
8
on the shaft
6
.
7
of the
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rhde250Rhde500Rhde800Rhde1250Rhde2500Rhde4000

Table of Contents