Cutting/Flaring the pipes
1 . Make sure that you have the required tools available. (pipe cutter, reamer, flaring tool and pipe holder)
2 . If you wish to shorten the pipes, cut it with a pipe cutter, taking care to ensure that the cut edge remains at a 90°
angle with the side of the pipe. Refer to the illustrations below for examples of edges cut correctly and incorrectly.
3 . To prevent any gas from leaking out, remove all burrs at the cut edge of the pipe, using a reamer.
4 . Slide a flare nut on to the pipe and modify the flare.
5 . Check that the flaring is correct, referring to the illustrations below for examples of incorrect flaring.
6 . Align the pipes and tighten the flare nuts first manually and then with a torque wrench, applying the following
torque.
Flare nut
Valve
Wrench(mm)
1/4"
17
3/8"
22
1/2"
26
5/8"
29
3/4"
36
• If the pipes require brazing ensure that OFN(Oxygen Free Nitrogen) is flowing through the system .
• Nitrogen blowing pressure range is 0 . 0 2 ~ 0 . 0 5MPa .
CAUTION
CAC_Global Duct Latin America_IM_EN_04680A-02.indd 21
Oblique
Outer Diameter (D)
ø6 . 3 5 mm(1/4")
ø9 . 5 2 mm(3/8")
ø12 . 7 0 mm(1/2")
ø15 . 8 8 mm(5/8")
ø19 . 0 5 mm(3/4")
Correct
Inclined
Valve cap
Pressure port cap
N•m
Wrench(mm)
N•m
Wrench(mm)
18
23
20
42
23
20
55
29
40
65
29
40
100
38
40
ENGLISH-21
Rough
Burr
Depth (A)
1 . 3 mm
1 . 8 mm
2 . 0 mm
2 . 2 mm
2 . 2 mm
Damaged
Cracked
Surface
Valve needle
N•m
Wrench(mm)
18
16~18
Allen(hex . ) 5
18
16~18
Allen(hex . ) 5
18
16~18
Allen(hex . ) 5
18
16~18
Allen(hex . ) 5
18
16~18
Allen(hex . ) 5
Uneven
Thickness
Pressure port
N•m
Wrench(mm)
N•m
9
-
0 . 3 4
9
-
0 . 3 4
13
-
0 . 3 4
13
-
0 . 3 4
13
-
0 . 3 4